B-10
Cisco ONS 15454 Reference Manual, R8.5.x
78-18106-01
Appendix B Administrative and Service States
B.3.3 Pluggable Equipment Service State Transitions
B.3.3 Pluggable Equipment Service State Transitions
The service state transitions for pluggable equipment are the same as for other equipment with the
exceptions listed in Table B-6 .
Note Pluggable equipment (pluggable interface modules [PIMs] and pluggable port modules [PPMs]) will
transition out of the UAS state when inserted if the software can read the EEPROM and identify
information on the pluggable equipment. If the soft ware cannot read the pluggable equipment, the
equipment is considered invalid and will not transition out of the UAS state.
OOS-MA,LPBK & MT
& OOG
Alarm/condition is raised. OOS-AUMA,FLT & LPBK &
MT & OOG
OOS-MA,MT Put the port or cross-connect in the IS
administrative state.
IS-NR
Put the port or cross-connect in the
IS,AINS administrative state.
OOS-AU,AINS
Put the port or cross-connect in the
OOS,DSBLD administrative state.
OOS-MA,DSBLD
OOS-MA,DSBLD & OOG for a
VCAT cross-connect
Put the port or cross-connect in a
loopback.
OOS-MA,LPBK & MT
Put the VCAT cross-connect in the
OOS,OOG administrative state.
OOS-MA,MT & OOG
Alarm/condition is raised. OOS-AUMA,FLT & MT
OOS-AUMA,FLT & MT & OOG
for a VCAT cross-connect
OOG-MA,MT & OOG Alarm/condition is raised. OOS-AUMA,FLT & MT & OOG
1. For a VCAT cross-connect, an IS-NR to OOS-AU,AINS transition will not occur with a Loss of Multiframe (LOM) or
Sequence Mismatch (SQM) condition on the member.
Table B-5 ONS 15454 Port and Cross-Connect Service State Transitions (continued)
Current Service State Action Next Service State
Table B-6 ONS 15454 Pluggable Equipment Service State Transitions
Current Service State Action Next Service State
IS-NR Reset the pluggable equipment. IS-NR
Provision an unsupported service rate. OOS- AU,MEA
Pluggable equipment does not work with
the board configuration.