B-11
Cisco ONS 15454 Reference Manual, R8.5.x
78-18106-01
Appendix B Administrative and Service States
B.3.3 Pluggable Equipment Service State Transitions
OOS-AU,AINS & UEQ Insert valid pluggable equipment. IS-NR
Insert pluggable equipment with the
incorrect rate.
OOS-AU,MEA
Pluggable equipment does not work with
the board configuration.
OOS-AU,MEA Delete unsupported service rate or
modify provisioning so that the pluggable
equipment is no longer a mismatch.
IS-NR
OOS-AU,UEQ Insert valid pluggab le equipment. IS-NR
OOS-AUMA,MEA & MT Delete unsupported service rate or
modify provisioning so that the pluggable
equipment is no longer a mismatch.
OOS-MA,MT
OOS-AUMA,MT & UEQ Insert valid pluggable equipment. OOS-MA,MT
OOS-AUMA,UAS Provision valid pluggable equipment. IS-NR
OOS-AUMA,UAS & UEQ Insert valid pluggable equipment. IS-NR
Insert pluggable equipment with the
incorrect rate.
OOS-AU,MEA
Pluggable equipment does not work with
the board configuration.
OOS-MA,MT Reset the pluggable equipment. OOS-MA,MT
Provision an unsupported service rate. OOS-AUMA,MEA & MT
Pluggable equipment does not work with
the board configuration.
Table B-6 ONS 15454 Pluggable Equipment Service State Transitions (continued)
Current Service State Action Next Service State