Chapter 5 Parameters and Defaults

Operating Parameters

CallerIdMethod

Description

This 32-bit parameter specifies the signal format to use for both FXS ports for generating Caller ID format. Possible values are:

Bits 0-1 (method)—0=Bellcore (FSK), 1=DTMF, values 2 and 3 are reserved. If method=0, set the following bits:

Bit 2—Reserved.

Bit 3 to 8—Maximum number of digits in phone number (valid values are 1 to 20; default is 12)

Bit 9 to 14—Maximum number of characters in name (valid values are 1 to 20; default is 15)

Bit 15—If this bit is enabled (it is by default), send special character O (out of area) to CID device if the phone number is unknown.

Bit 16—If this bit is enabled (it is by default), send special character P (private) to CID device if the phone number is restricted.

Bits 17 to 27—Reserved.

If method=1, set the following bits:

Bits 3-6—Start digit for known numbers (valid values are 12 for “A,” 13 for “B,” 14 for “C,” and

15for “D.”)

Bits 7-10—End digit for known numbers (valid values are 11 for “#,” 12 for “A,” 13 for “B,” 14 for “C,” and 15 for “D.”)

Bits 11—Polarity reversal before and after Caller ID signal (value of 0/1 disables/enables polarity reversal)

Bits 12-16—Maximum number of digits in phone number (valid values are 1 to 20)

Bits 17 to 19—Start digit for unknown or restricted numbers (valid values are 4 for “A,” 5 for “B,”

6for “C,” and 7 for “D.”)

Bits 20 to 22—End digit for unknown or restricted numbers (valid values are 3 for “#,” 4 for “A,” 5 for “B,” 6 for “C,” and 7 for “D.”)

Bits 23 to 24—Code to send to the CID device if the number is unknown (valid values are 0 for “00,”

1for “0000000000,” and 2 for “2.” 3 is reserved and should not be used.

Bits 25 to 26—Code to send to the CID device if the number is restricted (valid values are 0 for “10,” and 1 for “1.” 2 and 3 are reserved and should not be used.

Bits 27 to 31—Reserved.

Examples

The following examples are recommended values for the CallerID Method parameter:

USA=0x19e60

Sweden=0x0ff61 or 0x006aff61

Denmark=0x0fde1 or 0x033efde1

Value Type

Bitmap

Cisco ATA 186 and Cisco ATA 188 Analog Telephone Adaptor Administrator’s Guide (SIP)

 

OL-3410-01