Appendix C Cisco ATA Specifications

Electrical Specifications

Electrical Specifications

Table C-2 Electrical Specifications

Description

Specification

 

 

Power

0.25 to 7.5W (idle to peak)

 

 

DC input voltage

+5.0 VDC at 1.5A maximum

 

 

Power adaptor

Universal AC/DC

 

~3.3 x 2.0 x 1.3 in. (~8.5 x 5.0 x 3.2 cm)

 

~4.8 oz (135 g) for the AC-input external power adaptor

 

~4 ft (1.2 m) DC cord

 

6 ft (1.8 m) cord

 

UL/CUL, CE approved

 

Class II transformer

 

 

Environmental Specifications

Table C-3 Environmental Specifications

Description

Specification

 

 

Operating temperature

41 to 104° F (5 to 40° C)

 

 

Storage temperature

–4 to 140° F (–20 to 65° C)

 

 

Relative humidity

10 to 90% noncondensing, operating, and nonoperating/storage

 

 

Immunity Specifications

EN50082-1, including the following:

EN61000-3-2, Electromagnetic Compatibility

EN61000-3-3, Electromagnetic Compatibility

EN61000-4-2, ESD

EN61000-4-3, Radiated Immunity

EN61000-4-4, Burst Transients

EN61000-4-5, Surge

EN61000-4-6, Injected RF

EN61000-4-11, Dips and Sags

Cisco ATA 186 and Cisco ATA 188 Analog Telephone Adaptor Administrator’s Guide (SIP)

 

C-2

OL-3410-01

 

 

 

Page 178
Image 178
Cisco Systems 188, 186 manual Electrical Specifications, Environmental Specifications, Immunity Specifications