5-40
Cisco ATA 186 and Cisco ATA 188 Analog Telephone Adaptor Administrator’s Guide (SIP)
OL-3410-01
Chapter5 Parameters and Defaults
Optional Feature Parameters
Dial Plan Example 1 (Default Dial Plan)
The following dial plan:
*St4-|#St4-|911|1>#t8.r9t2-|0>#t811.rat4-|^1t4>#.-
consists of the following rules:
*St4-—If the first digit entered is *, all other dial plan rules are voided. Additional digits can be
entered after the initial * digit, and the timeout before automatic dial string send is four seconds.
#St4—Same as above, except with # as the initial digit entered.
911—If the dial string 911 is entered, send it immediately.
1>#t8.r9t2—If the first digit entered is 1, the timeout before automatic send is eight seconds. The
terminating character # can be entered at any time to manually send the dial string. After the 11th
digit is entered, the timeout before an automatic send changes to two seconds. The user can enter
more digits until the dial string is sent by the timeout or by the user entering the # character.
0>#t811.rat4—If the first digit entered is 0, the timeout before aut omatic send is eight seconds, and
the terminating character # can be entered at any time to manually send the dial string. If the first
three digits entered are 011, then, after an additional 11 digits are entered, the timeout before an
automatic send changes to four seconds. The user can enter more digits until the dial string is sent
by the timeout or by the user entering the # character.
^1t4>#.—If the first digit entered is anything other than 1, the timeout before an automatic send is
four seconds. The terminating character # can be entered at any time to manually send the dial string.
The user can enter more digits until the dial string is sent by the timeout or by the user entering the
# character.
Dial Plan Example 2
The following dial plans:
.t7>#......t4-|911|1t7>#..........t1-|0t4>#.t7-
or
.t7>#r6t4-|911|1t7>#.r9t1-|0t4>#.t7-
consist of the following rules:
.t7>#r6t4-—You must enter at least one digit. After the first digit is entered and matched by the dial
plan, the timeout before an automatic send is seven seconds, and the terminating character # can be
entered at any time to manually send the dial string. Afte r seven digits are entered, the timeout
before an automatic send changes to two seconds. The - symbol at the end of the rule allows further
digits to be entered until the dial string is sent by the timeout or the user entering the # character.
911—If the dial string 911 is entered, send this string imme diately.
1t7>#.r9t1—If the first digit entered is 1, the timeout before an automatic send is seven seconds,
and the terminating character # can be entered at any time to manually send the dial string. After the
11th digit is entered, the timeout before an automatic send changes to one second. The user can enter
more digits until the dial string is sent by the timeout or by the user entering the # character.
0t4>#.t7—If the first digit entered is 0, the timeout before an automatic send is four seconds, and
the terminating character # can be entered at any time to manually send the dial string. After the
second digit is entered, the timeout before an automatic send changes to seven seconds. The user
can enter more digits until the dial string is sent by the timeout or by the user entering the # character.