Chapter 5 Parameters and Defaults

Operating Parameters

AutMethod

Description

This parameter is not used for SIP.

TimeZone

Description

This parameter is the timezone offset from Greenwich Mean Time (GMT) for time-stamping incoming calls with local time (to use for Caller ID display, for example).

Local time is generated by the following formula:

Local Time=GMT + TimeZone, if TimeZone <= 12

Local Time=GMT + TimeZone - 25, if TimeZone > 12

Value Type

Integer

Range

0-24

Default

17

Voice Configuration Menu Access Code

302

NTPIP

Description

This parameter is the NTP IP address, required if DHCP server does not provide one.

The Cisco ATA requires an NTP Server from which to obtain Coordinated Universal Time (UTC) to time-stamp incoming calls (H.323 and SIP) to drive an external Caller-ID device.

DHCP may also supply a NTP server. If NTPIP is specified, it overwrites the value supplied by DHCP. NTPIP is ignored if its value is 0 or 0.0.0.0.

The user must not specify a port parameter. The Cisco ATA uses the default NTP port only.

Value Type

IP address

Default

0.0.0.0

Voice Configuration Menu Access Code

141

Cisco ATA 186 and Cisco ATA 188 Analog Telephone Adaptor Administrator’s Guide (SIP)

5-30

OL-3410-01

 

 

Page 102
Image 102