5-41
Cisco Wide Area Application Engine 7326 Hardware Installation Guide
OL-6831-02
Chapter5 Troubleshooting the System Hardware
Symptoms and Solutions
166-400-000
System
Management:
Failed
ISMP self-test result failed tests:
x where x = Flash, RAM, or
ROM.
1. Reflash or update firmware for ISMP.
2. Check the system board.
180-XXX-000 Diagnostics LED failure. Run diagnostic panel LED test for the failing
LED.
180-XXX-001 Failed front LED panel test. 1. Check the operator information panel.
2. Check the system board.
180-XXX-002 Failed diagnostic LED panel
test.
1. Check the diagnostic panel.
2. Check the system board.
180-361-003 Failed fan LED test. 1. Check the fan(s).
2. Check the system board.
180-XXX-003 Failed system board LED test. Check the system board.
180-XXX-005 Failed SCSI backplane LED test. 1. Check the SCSI backplane.
2. Check the SCSI backplane cable.
3. Check the system board.
201-XXX-0NN Failed memory test. 1. Check the DIMM location slots 1–6 where
nn = DIMM location.
Note nn 1 = DIMM 1
nn 2 = DIMM 2
nn 3 = DIMM 3
nn 4 = DIMM 4
2. Check the system board.
201-XXX-999 Multiple DIMM failure; see
error text.
1. See error text for failing DIMMs.
2. Check the system board.
202-XXX-001 Failed system cache test. 1. Check VRM 1.
2. Check microprocessor 1.
Table5-8 Error Code Definitions (continued)
Error Code Problem Action