AppendixA Wide Area Application Engine 7326 Hardware Specifications
Appliance Specifications
A-4
Cisco Wide Area Application Engine 7326 Hardware Installation Guide
OL-6831-02
Environment Air temperature:
Server on: 50 to 95°F (10 to 35°C);
altitude: 0 to 2133 m (6998.0 ft)
Server off: 50° to 109.4°F (10° to 43°C);
maximum altitude: 2133 m (6998.0 ft)
Humidity
Server on: 8% to 80%
Server off: 8% to 80%
1Acoustical noise
emissions
Declared sound power, idle: 6.6 bel2
Declared sound power, operating: 6.6 bel
3Heat Output Minimum configuration: 1230 Btu4 (360 watts)
Maximum configuration: 2840 Btu (830 watts)
1. These levels were measured in controlled acoustical environments according to the procedures
specified by the American National Standards Institute (ANSI) S12.10 and ISO 7779 and are
reported in accordance with ISO 9296. Actual sound-pressure levels in a given location might
exceed the average values stated because of room reflections and other nearby noise sources. The
declared sound-power levels indicate an upper limit, below which a large number of computers
will operate.
2. In acoustics, logarithm of the ratio of a quantity to a reference quantity of the same kind is called
a level. The base of the logarithm (always ten, unless otherwise specified), the reference quantity,
and the kind of level shall be specified.bel is a unit of level when the base of the logarithm is ten,
and the quantities concerned are proportional to power.
3. Power consumption and heat output vary depending on the number and type of optional features
installed, and the power-management optional features in use.
4. British Thermal Unit