5-55
Cisco Wide Area Application Engine 7326 Hardware Installation Guide
OL-6831-02
Chapter5 Troubleshooting the System Hardware
Symptoms and Solutions
962 Parallel port error. 1. Disconnect the external cable on the parallel
port.
2. Check the system board.
11XX System board serial port 1 or 2 error. 1. Disconnect the external cable on the serial
port.
2. Check the system board.
1301 I2C cable to front panel not found. 1. Check the cable.
2. Check the front panel.
3. Check the power switch assembly.
4. Check the system board.
1302 I2C cable from system board to
power up and reset switches not
found.
1. Check the cable.
2. Check the power switch assembly.
3. Check the system board.
1303 I2C cable from system board to
power backplane not found.
1. Check the cable.
2. Check the power cage assembly.
3. Check the system board.
1304 I2C cable to diagnostic LED board
not found.
1. Check the power switch assembly.
2. Check the system board.
1600 The system management processor is
not functioning.
1. Complete the following steps before replacing
a FRU:
a. Ensure that a jumper is not installed on
J34.
b. Remove the AC power to the device, and
wait 20 seconds.
c. Reconnect the AC power and wait
30 seconds.
d. Power up the device.
2. Check the system board.
Table5-21 POST Error Codes (continued)
Error Code Symptom Cause and Action