5-45
Cisco Wide Area Application Engine 7326 Hardware Installation Guide
OL-6831-02
Chapter5 Troubleshooting the System Hardware
Symptoms and Solutions
Table5-11 Hard Disk Drive Problems
Symptom Cause and Action
Not all drives are recognized
by the hard disk drive
diagnostic test (fixed disk
test).
1. Remove the first drive not recognized and try the hard disk drive
diagnostic test again.
2. If the remaining drives are recognized, the drive that you removed
needs to be replaced.
System stops responding
during hard disk drive
diagnostic test.
1. Remove the hard disk drive being tested when the device stopped
responding and try the diagnostic test again.
2. If the hard disk drive diagnostic test runs successfully, the drive
that you removed needs to be replaced.
Table5-12 General Problems
Symptom Cause and Action
Problems such as broken cover
locks or indicator LEDs not
working.
Broken component. Call your service representative.
Table5-13 Intermittent Problems
Symptom Cause and Action
A problem occurs only
occasionally and is difficult to
detect.
1. Verify the following items:
a. All cables and cords are connected securely to the rear of the
device and attached hardware options.
b. When the device is powered on, air is flowing fromthe rear
of the device at the fan grille. If there isno airflow, the fan is
not working. This causes the device to overheat and shut
down.
c. Ensure that the SCSI bus and devices are configured correctly
and that the last external device in each SCSI chain is
terminated correctly.
2. Check the system error log.