Symptoms and Solutions
00180500 PCI option ROM checksum error. 1. Remove the failing PCI card.
2. Check the system board.
00180600 PCI to PCI bridge error. 1. Move the failing adapter to slot 1.
2. Check the adapter.
3. Check the system board.
00180700,
00180800
General PCI error. 1. Check the system board.
2. Check the PCI card.
00181000 PCI error. 1. Check the adapter.
2. Check the system board.
01295085 ECC checking hardware test error. 1. Check the system board.
2. Check the microprocessor.
01298001 No update data for microprocessor 1. 1. Ensure that all processors have the same cache
size.
2. Check microprocessor 1.
01298002 No update data for microprocessor 2. 1. Ensure that all processors have the same cache
sizes, dock speeds, and clock frequencies.
2. Check microprocessor 2.
01298101 Bad update data for
microprocessor 1.
1. Ensure that all processors have the same cache
sizes, dock speeds, and clock frequencies.
2. Check microprocessor 1.
01298102 Bad update data for
microprocessor 2.
1. Ensure that all processors have the same cache
sizes, dock speeds and clock frequencies.
2. Check microprocessor 2.
19990301 Hard disk sector error. 1. Check the hard disk drive.
2. Check the SCSI backplane.
3. Check the cable.
4. Check the system board.
Table5-21 POST Error Codes (continued)
Error Code Symptom Cause and Action