Cisco 7401ASR Installation and Configuration Guide
OL-5419-01 B0
AppendixA Specifications Alarm Port
Alarm Port
The dry relay alarm port operates up to 50V AC/DC maximum and up to 80 mA maximum. Total power
dissipation should not exceed 300 milliwatts. The normally closed position will have from 15 to 30 ohms
resistance. The open position will be greater than 1 megohm. The A larm condition is the closed position.
This port is a switch so that the cable connector can be inserted in either orientation.
Lithium Battery Caution
This caution is required although the Cisco 7401ASR ro uter h as no i nte rnal field repl ac eable un its.
Caution Danger of explosion if battery is incorrectly replaced.
Replace only with the same or equivalent type recommended by the manufacturer. Dispose
of used batteries according to the manufacturers instructions.