2-22
Cisco 7401ASR Installation and Configuration Guide
OL-5419-01 B0
Chapter2 Rack-Mounting, Tabletop Installation, and Cabling
Attaching the Alarm Port Cable
Attaching the Alarm Port Cable
Figure2-15 Connecting the Alarm Port Cable
If you have an alarm system, attach the alarm cable to the Cisco 7401ASR router alarm port. The alarm
port cable is not provided by Cisco Systems. Insert the cable connector into the alarm port. The cable
connector cannot be incorrectly inserted into the al arm port.
The alarm port is used to monitor fatal or severe errors that cause CiscoIOS to crash. The alarm port is
connected to a normally closed solid state relay. CiscoIOS writes to a hardware port and the relay
contact opens. If the system enters into a ROMmon or watchdog r eset state, the relay co ntacts clo se. The
closing contacts alert the alarm annunciator or m onito r t hat a C isc o IOS crash has occurred.
If interfaces fail or other non-fatal errors occur, the alarm port does not respond. Continue to use SNMP
to manage these types of errors.
For alarm port specifications, see AppendixA, Specifications, the Alarm Port section on page A-9.
Using the Cable-Management Bracket
Figure2-16 Securing Interface Cables through the Cable-Management Bracket
Secure port adapter interface cables and input/output cables by placing them through th e
cable-management bracket.
1Alarm port
57725
1
1Input/output cables 2Cable-management bracket
ENABLED
RX CELLS
RX CARRIER
RX ALARM
TX
RX
ENHANCED ATM
57581
1
2