Step 8 Connect the other ends of the terminal block cables to the site ground connection. Move the circuit-breaker switch to the On position ().

This completes the procedure for connecting DC-input power. Your installation is complete. Proceed to the “Start the System” section on page 14 to start the router.

Note After powering off the router, wait a minimum of 30 seconds before powering it on again.

Verifying Power Supply Operation

Follow this procedure to verify power supply is operating correctly.

Step 1 Check that the power supply LEDs are:

INPUT OK is green

FAN OK is green

OUTPUT FAILED is not illuminated

Step 2 To ensure that the power supply state is OK, type the show platform command. This output sample is from a Cisco ASR1004 router.

MCP_SCAL_R1#sho plat

Chassis type: ASR1004

The following output displays:

Slot

Type

State

Insert Time

0

ASR1000-SIP10

ok

00:03:19

1

ASR1000-SIP10

ok

00:03:19

RP0

ASR1000-RP1

ok,active

00:03:19

FP0

ASR1000-ESP20

ok,active

00:03:19

P0

ASR1004-PWR-AC

ok

00:02:50

P1

ASR1004-PWR-AC

ps, fail

00:02:50

Slot

CPLD Version

Firmware Version

0

07091401

12.2(33r)XN2

1

07091401

12.2(33r)XN2

RP0

08060301

12.2(0:0)

 

FP0

08041102

12.2(33r)XN2

MCP_SCAL_R1#

If the LEDs indicate a power problem or the power supply state is ps,fail, then contact a customer service representatives for assistance or additional instructions.

Start the Cisco ASR 1004 Router

After installing your Cisco ASR 1004 Router and connecting cables, start the router as follows.

Step 1 Check for the following:

20

Page 20
Image 20
Cisco Systems quick start Verifying Power Supply Operation, Start the Cisco ASR 1004 Router