Step 8 Connect the other ends of the terminal block cables to the site ground connection. Move the
This completes the procedure for connecting
Note After powering off the router, wait a minimum of 30 seconds before powering it on again.
Verifying Power Supply Operation
Follow this procedure to verify power supply is operating correctly.
Step 1 Check that the power supply LEDs are:
•INPUT OK is green
•FAN OK is green
•OUTPUT FAILED is not illuminated
Step 2 To ensure that the power supply state is OK, type the show platform command. This output sample is from a Cisco ASR1004 router.
MCP_SCAL_R1#sho plat
Chassis type: ASR1004
The following output displays:
Slot | Type | State | Insert Time |
0 | ok | 00:03:19 | |
1 | ok | 00:03:19 | |
RP0 | ok,active | 00:03:19 | |
FP0 | ok,active | 00:03:19 | |
P0 | ok | 00:02:50 | |
P1 | ps, fail | 00:02:50 | |
Slot | CPLD Version | Firmware Version | |
0 | 07091401 | 12.2(33r)XN2 | |
1 | 07091401 | 12.2(33r)XN2 | |
RP0 | 08060301 | 12.2(0:0) |
|
FP0 | 08041102 | 12.2(33r)XN2 |
MCP_SCAL_R1#
If the LEDs indicate a power problem or the power supply state is ps,fail, then contact a customer service representatives for assistance or additional instructions.
Start the Cisco ASR 1004 Router
After installing your Cisco ASR 1004 Router and connecting cables, start the router as follows.
Step 1 Check for the following:
20