20
Step 8 Connect the other ends of the terminal block cables to the site ground connection. Move the circuit-breaker switch to
the On position (|).
This completes the procedure for connecting DC-input power. Your installation is complete. Proceed to the “Start the System”
section on page 14 to start the router.
Note After powering off the router, wait a minimum of 30 seconds before powering it on again.

Verifying Power Supply Operation

Follow this procedure to verify power supply is operating correctly.
Step 1 Check that the power supply LEDs are:
INPUT OK is green
FAN OK is green
OUTPUT FAILED is not illuminated
Step 2 To ensure that the power supply state is OK, type the show platform command. This output sample is from a Cisco
ASR1004 router.
MCP_SCAL_R1#sho plat
Chassis type: ASR1004
The following output displays:
MCP_SCAL_R1#
If the LEDs indicate a power problem or the power supply state is ps,fail, then contact a customer service representatives for
assistance or additional instructions.

Start the Cisco ASR 1004 Router

After installing your Cisco ASR 1004 Router and connecting cables, start the router as follows.
Step 1 Check for the following:
Slot Type State Insert Time
0 ASR1000-SIP10 ok 00:03:19
1 ASR1000-SIP10 ok 00:03:19
RP0 ASR1000-RP1 ok,active 00:03:19
FP0 ASR1000-ESP20 ok,active 00:03:19
P0 ASR1004-PWR-AC ok 00:02:50
P1 ASR1004-PWR-AC ps, fail 00:02:50
Slot CPLD Version Firmware Version
0 07091401 12.2(33r)XN2
1 07091401 12.2(33r)XN2
RP0 08060301 12.2(0:0)
FP0 08041102 12.2(33r)XN2