Torque is from 4.425 in.-lb (.5 N-m) to 5.310 in-lb (.6 N-m).

Chapter 3 Installing the Cisco ASR 903 Router

Installing the Power Supply

Step 5 Use a ratcheting torque screwdriver to torque the terminal block plug captive screw (above the installed wire lead) from 4.425 in.-lb (.5 N-m) to 5.310 in-lb (.6 N-m) as shown in Figure 3-18.

Figure 3-18 Torquing the DC Power Supply Terminal Block Plug Screws

1

1

207764

Torque is from 4.425 in.-lb (.5 N-m) to 5.310 in-lb (.6 N-m).

Step 6 Repeat Step 4 through Step 5 for the remaining DC input power source wire and the ground wire. Figure 3-19shows the wiring completed for a terminal block plug.

Figure 3-19 Inserting the DC Power Supply Terminal Block Plug in the Block Header