Cisco Systems ASR 903 manual Installing the Terminal Block, 3-20

Models: ASR 903

1 118
Download 118 pages 26.92 Kb
Page 70
Image 70
Installing the Terminal Block

Chapter 3 Installing the Cisco ASR 903 Router

Installing the Power Supply

Figure 3-16 Installing the DC Power Supply

GE-0

GE-1

GE-2

GE-3

GE-4

GE-5

GE-6

GE-7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PWR

 

 

 

 

 

 

 

 

 

FAN TEMP

 

 

 

 

 

 

 

STAT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CRIT MAJ MIN

GE-0

GE-1

GE-2

GE-3

GE-4

GE-5

GE-6

GE-7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PWR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

STAT

 

 

 

 

 

 

 

 

 

 

GE-0

GE-1

GE-2

GE-3

GE-4

GE-5

GE-6

GE-7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PWR

RUDY RSP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

STAT

 

 

 

 

 

 

 

 

 

SYNC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ACT

 

 

 

 

 

 

 

PWR

 

 

1PPS

1PPS

1OMHZ

1OMHZ

 

 

 

PWR

 

 

 

 

 

 

 

MEM

CONSOLE

TOD

BITS

MGMT

STAT

 

 

 

 

 

 

 

 

IN

OUT

IN

OUT

 

 

 

 

 

 

 

STAT

 

 

 

 

 

 

 

 

ENET

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

L 0 S

L 1 S

L 2 S

L 3 S

L 4 S

L 5 S

L 6 S

L 7 S

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PWR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

STAT

 

 

 

 

 

 

 

 

 

 

L 0 S

L 1 S

L 2 S

L 3 S

L 4 S

L 5 S

L 6 S

L 7 S

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PWR

 

 

 

 

 

 

 

 

 

ALARM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

STAT

 

 

 

 

 

 

 

 

 

 

L 0 S

L 1 S

L 2 S

L 3 S

L 4 S

L 5 S

L 6 S

L 7 S

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INPUT

24V—60V

28A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OK

 

 

 

 

 

 

 

 

OUTPUT

FAIL

282340

Step 5 Tighten the captive installation screws of the power supply. The recommended maximum torque is 5.5 in.-lb (.62 N-m).

If you are installing a redundant DC power supply, repeat these steps for the second power source.

Installing the Terminal Block

Perform the following procedure to install the terminal block:

Step 1 Locate the terminal block plug.

Step 2 Use a wire-stripping tool to strip the ends of each of the two wires coming from the DC-input power source to 0.27 inch (6.6 mm) ± 0.02 inch (0.5 mm) and the wire for grounding. Do not strip more than

0.29inch (7.4 mm) of insulation from the wire. Stripping more than the recommended amount of wire can leave behind exposed wire from the terminal block plug after installation.

Step 3 Identify the ground, positive, and negative feed positions for the terminal block connection. The recommended wiring sequence is:

a.Ground lead wire (right)

b.Negative (-) lead wire (left)

c.Positive (+) lead wire (middle)

 

Cisco ASR 903 Router Hardware Installation Guide

3-20

OL-25178-04

Page 70
Image 70
Cisco Systems ASR 903 manual Installing the Terminal Block, 3-20