Chapter 1 Product Overview

Front Panel

When an AC-power-supply module is installed, the AC 1 and AC 2 LEDs show which power supply is on (see Figure 1-7).

Table 1-5

AC-Power-Supply LEDs

 

 

Color

System Status

 

 

Off

AC-power-supply module is not installed.

 

 

Green

AC-power-supply module is installed, and AC-power input (1 or 2) is present.

 

 

Amber

AC-power-supply module is installed, and AC-power input (1 or 2) is not present.

 

 

When DC-power-supply modules are installed, the DC A and DC B LEDs show which power supply is on (see Figure 1-7).

Table 1-6

DC-Power-Supply LEDs

 

 

Color

System Status

 

 

Off

DC-power-supply module is not installed. A DC-power-supply module is installed, and a

 

single DC-power input (A or B) is used and the CLI is configured to allow a single

 

DC-input feed.

 

 

Green

DC-power-supply module is installed, and the DC-power input (A or B) is present and is

 

in the operating range.

 

 

Amber

DC-power-supply module is installed, and the DC-power input (A or B) is not present or

 

is not in the operating range.

 

 

Ethernet Management Port LED

Table 1-7

Ethernet Management Port LED

 

 

 

Color

 

System Status

 

 

 

Off

 

No link, or port was administratively shut down.

 

 

 

Green

 

Link present but not sending or receiving data.

 

 

 

Blinking green

 

Activity. Port is sending or receiving data.

 

 

 

Alternating

 

Link fault. Error frames can affect connectivity, and errors such as excessive

green/amber

 

collisions, CRC1 errors, and alignment and jabber errors2 are monitored for a

 

 

link-fault indication.

 

 

 

1.CRC = cyclic redundancy check.

2.Jabber errors occur when data packets exceed the prescribed lengths.

 

Cisco ME 3400E Ethernet Access Switch Hardware Installation Guide