A P P E N D I X A

Technical Specifications

Environmental Ranges and Technical Specifications for the Switch

Environmental and Technical Specifications for the Power-Supply Modules

Environmental Ranges and Technical Specifications for the Switch

Table A-1

Environmental Ranges for the Switch

 

 

Environmental Ranges

 

 

 

Operating temperature

See Table A-2,Table A-3, and Table A-4.

 

 

Storage temperature

–13 to 158°F (–25 to 70°C).

 

 

Relative humidity

10 to 85% (noncondensing).

 

 

Operating altitude

Up to 10,000 ft (3049 m).

 

 

 

Storage altitude

 

Up to 15,000 ft (4570 m).

 

 

 

The operating temperature for the switch varies depending on the type of SFP module and the number of power-supply modules installed in the switch. In Table A-2, Table A-3, and Table A-4, Yes means that the operating temperature range is supported, and No means it is not supported.

 

 

Table A-2

Operating Temperatures for the Cisco ME 3400EG-2CS-A

 

 

 

 

 

 

 

 

 

SFP Module

 

32 to 131°F (0 to 55°C)

32 to 140°F (0 to 60°C)

 

 

 

 

 

 

 

 

GLC-FE-100FX

Yes

Yes

 

 

 

 

 

 

 

 

GLC-FE-100LX

Yes

Yes

 

 

 

 

 

 

 

 

GLC-FE-100EX

Yes

Yes

 

 

 

 

 

 

 

 

GLC-FE-100ZX

Yes

Yes

 

 

 

 

 

 

 

 

GLC-FE-100BX-D

Yes

Yes

 

 

 

 

 

 

 

 

GLC-FE-100BX-U

Yes

Yes

 

 

 

 

 

 

 

 

 

GLC-SX-MM

 

Yes

No

 

 

 

 

 

 

 

 

 

GLC-LH-SM

 

Yes

No

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cisco ME 3400E Ethernet Access Switch Hardware Installation Guide

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OL-16447-01

 

 

 

 

 

A-1

 

 

 

 

 

 

 

 

Page 75
Image 75
Cisco Systems Cisco ME 3400E manual Environmental Ranges, SFP Module 32 to 131F 0 to 55C 32 to 140F 0 to 60C