A-1
Cisco ME 3400E Ethernet Access Switch Hardware Installation Guide
OL-16447-01
APPENDIX
A

Technical Specifications

Environmental Ranges and Technical Specifications for the Switch
Environmental and Technical Specifications for the Power-Supply Modules

Environmental Ranges and Technical Specifications for the

Switch

The operating temperature for the switch varies depending on the type of SFP module and the number
of power-supply modules installed in the switch. In Table A-2, Table A-3 , and Table A-4, Yes means that
the operating temperature range is supported, and No means it is not supported.
Table A-1 Environmental Ranges for the Switch
Environmental Ranges
Operating temperature See Table A-2, Tabl e A-3, and Tabl e A-4.
Storage temperature –13 to 158°F (–25 to 70°C).
Relative humidity 10 to 85% (noncondensing).
Operating altitude Up to 10,000 ft (3049 m).
Storage altitude Up to 15,000 ft (4570 m).
Table A-2 Operating Temperatures for the Cisco ME 3400EG-2CS-A
SFP Module 32 to 131°F (0 to 55°C) 32 to 140°F (0 to 60°C)
GLC-FE-100FX Yes Yes
GLC-FE-100LX Yes Yes
GLC-FE-100EX Yes Yes
GLC-FE-100ZX Yes Yes
GLC-FE-100BX-D Yes Yes
GLC-FE-100BX-U Yes Yes
GLC-SX-MM Yes No
GLC-LH-SM Yes No