Chapter 3 Installing and Removing AC- and DC-Power-Supply Modules

Power Supply Settings

Power Supply Settings

Use the no power-supplyglobal configuration command (the default) when installing one power-supply module. The switch does not send an alarm when the second power-supply module is missing.

Use the power-supply dual global configuration command when installing two power-supply modules. When both are operating properly, all applicable LEDs are green, and the switch does not send an alarm. If a power-supply module is missing, the switch sends an alarm. An error message appears and the appropriate power-supply LED turns red.

Use the power-supply dual dc-feedglobal configuration command when two DC-input feeds are connected to the DC-power source. When both are operating properly, all the applicable LEDs are green and the switch does not send an alarm. If only one DC-input feed is connected, and there is at least one DC-power-supply module installed, the switch sends an alarm. An error message appears and the DC-power-supply LED for the missing DC-input feed turns amber. The LED for the connected DC-input feed turns green.

Use the no power-supply dual dc-feedglobal configuration command when only one DC-input feed is connected. The switch does not send an alarm when the second DC-input feed is not connected.

See the switch software configuration guide and switch command reference for more details on these settings.

 

 

Cisco ME 3400E Ethernet Access Switch Hardware Installation Guide

 

 

 

 

 

 

OL-16447-01

 

 

3-17

 

 

 

 

 

Page 67
Image 67
Cisco Systems Cisco ME 3400E manual Power Supply Settings