Viewing Statistics
Configuring RMON History
ESW 500 Series Switches Administration Guide 421
Rising Event — Selects an event which is defined in the Events table that
triggers the rising threshold alarm. The Events Table is displayed in the

RMON

Events Page

.
Falling Threshold — Displays the falling counter value that triggers the falling
threshold alarm. The falling threshold is graphically presented on top of the
graph bars. Each monitored variable is designated a color.
Falling Event — Selects an event which is defined in the Events table that
triggers the falling threshold alarm. The Events Table is displayed in the

RMON

Events Page

.
Startup Alarm — Displays the trigger that activates the alarm generation.
Rising is defined by crossing the threshold from a low-value threshold to a
higher-value threshold.
-

Rising Alarm

— The rising counter value that triggers the rising threshold
alarm.
-

Falling Alarm

— The falling counter value that triggers the falling
threshold alarm.
-

Rising and Falling

— The rising and falling counter values that trigger the
alarm.
Interval — Defines the alarm interval time in seconds.
Owner — Displays the device or user that defined the alarm.
STEP 3 Define the relevant fields.
STEP4 Click Apply. The RMON alarm is added, and the device is updated.

Modifying RMON Alarm Settings

STEP1 Click Statistics > RMON (Remote Management) > Alarms. The

RMON Alarms Page

opens:
STEP 2 Click the Edit Button. The

Edit RMON Alarm Page

opens: