Cisco Systems ISR4451XK9 manual Replacing a Fan Tray, Replacing the Cisco ISR 4451-X Fan Tray

Models: ISR4451XK9

1 160
Download 160 pages 7.47 Kb
Page 150
Image 150

Chapter 6 Installing and Upgrading Internal Modules and FRUs

Replacing a Fan Tray

Warning Care should be taken while removing the power supplies and power inverters (especially in boost mode of operation). If the total power consumption is higher than can be supported by one power supply alone and in this condition a power supply is removed, the hardware can be damaged. This may then result in the system being unstable or unusable.

The following messages are expected behavior when you try to reload or insert a PoE supply in a router with Ethernet Switch Network Module:

Aug 10 18:29:40.331: %ILPM_FAULT-5-ILPM_NOTICE: Notice: Inline power supply is being started.

*Aug 10 18:29:40.331: %ILPM_FAULT-5-ILPM_WARNING: Warning: Ethernet Switch Network Modules with PoE Support need to be reloaded to function properly.

*Aug 10 18:29:40.691: %SYS-5-RESTART: System restarted -- Cisco IOS Software, C2900 Software (C2900-UNIVERSALK9-M), Version 15.0(1)M2, RELEASE SOFTWARE (fc2)

This warning message is not an indication of any error in the system but a warning upon system reload or PoE power supply restoration.

Upon PoE power supply insertion, inline power supply restores automatically in the router. After the insertion, resets are needed for the switch modules in the router for the PoE supply to work properly.

If there are two PoE supplies, the power supplies can operate in a boost mode or redundant mode. In a boost mode, the total power supplied is a sum of the two power supplies capacity. In a redundant mode, if one of the PoE supply fails, the other PoE will supply power.

Cisco ISR 4451-X Power and RPS Error Messages

There are several RPS error messages unique to the Cisco ISR 4451-Xs. The messages appear on the router console terminal.

Replacing a Fan Tray

The Cisco ISR 4451-Xs have hot-swappable fan trays that are field replaceable units (FRUs). The fan tray includes all of the router fans in one assembly. If a fan fails, replace the tray using a flat-blade or Phillips screwdriver.

Before Hot-Swapping a Fan Tray

Before hot-swapping a fan tray, read the safety precautions below.

Read the entire procedure and have the required tools available.

Do not attempt the hot-swap in ambient air temperature above 90°F (32°C).

Do not attempt the hot-swap at an altitude above 6000 feet (1829 meters).

When the router is being operated, it is recommended to change the fans in the Cisco ISR 4451-X within 2 minutes to ensure the router does not overheat:

Replacing the Cisco ISR 4451-X Fan Tray

To replace the fan tray, complete the following steps:

 

 

Hardware Installation Guide for the Cisco 4451-X Integrated Services Router

 

 

 

 

 

 

OL-27644-01

 

 

6-34

 

 

 

 

 

Page 150
Image 150
Cisco Systems ISR4451XK9 Replacing a Fan Tray, Replacing the Cisco ISR 4451-X Fan Tray, Before Hot-Swapping a Fan Tray