Setup Command Parameters (continued)

Chapter 4 Connect the Management Interfaces and Perform Initial System Configuration

Perform the Initial System Configuration

Table 4-1

Setup Command Parameters (continued)

 

 

 

Parameter

 

Definition

 

 

Access Control List number

How many ACLs will be necessary? What IP

 

 

addresses will be permitted/denied access for each

 

 

management interface? You may want ACLs for

 

 

the following:

 

 

Any IP access

 

 

Telnet access

 

 

SNMP GET access

 

 

SNMP SET access

 

 

list entries (maximum 20 per list)

IP address, and whether permitted or denied

 

 

access.

 

 

 

IP access ACL

 

ID number of the ACL controlling IP access.

 

 

 

telnet ACL

 

ID number of the ACL controlling telnet access.

 

 

SNMP agent status

Enable or disable SNMP management.

 

 

GET community names

Community strings to allow GET access and

 

 

associated ACLs (maximum 20).

 

 

SET community names

Community strings to allow SET access and

 

 

associated ACLs (maximum 20).

 

 

trap managers (maximum 20)

Trap manager IP address, community string, and

 

 

SNMP version.

 

 

Authentication Failure trap status

Sets the status of the Authentication Failure traps.

 

 

enterprise traps status

Sets the status of the enterprise traps.

 

 

system administrator

Name of the system administrator.

 

 

 

Topology Configuration

 

 

 

 

connection mode

Is the SCE 1000 installed using inline topology or

 

 

receive-only topology using an optical splitter?

 

 

link bypass mode on operational status

When the SCE 1000 is operational, should it

 

 

bypass traffic or not?

 

 

link bypass mode on non-operational status

When the SCE 1000 is not operational, should it

 

 

bypass traffic or cut it off?

 

 

 

priority

 

If this is a cascaded topology, is this SCE 1000 the

(cascade topology only)

primary or secondary SCE 1000?

 

 

 

 

operational status of the SCE after abnormal boot

After a reboot due to a failure, should the SCE

 

 

1000 remain in a Failure status or move to

 

 

operational status provided no other problem was

 

 

detected?

 

 

 

 

Following are some general instructions regarding the setup dialog:

All default values appear in square brackets [default] .

If no value appears in the brackets [], or more than one option appears [ yes/no ], then this parameter does not have a default value.