Image 60
SCE 1000 is fully operational (as

Chapter 8 Troubleshoot Startup Problems

SCE 1000 Operational Status

Table 8-1

SCE 1000 Operational States (continued)

 

 

 

 

SCE 1000 Operational Status

Description

Status LED State

 

 

 

 

Warning

 

SCE 1000 is fully operational (as

Flashing orange

 

 

above) but one of the following

 

 

 

occurred:

 

 

 

Line ports (GBE ports) to

 

 

 

 

the link are down

 

 

 

Management port link is

 

 

 

 

down

 

 

 

Temperature raised above

 

 

 

 

threshold

 

 

 

Voltage not in required

 

 

 

 

range

 

 

 

Fans problem

 

 

 

Power supply problem

 

 

 

Insufficient space on the

 

 

 

 

disk

 

 

 

Note If the condition that

 

 

 

 

caused the SCE 1000 to

 

 

 

 

be in Warning state is

 

 

 

 

resolved (for example,

 

 

 

 

link is up) the SCE 1000

 

 

 

 

reverts to Operational

 

 

 

 

state.

 

 

 

 

 

Failure

 

System is in Failure state after

Red

 

 

Boot due to one of the following

 

 

 

conditions:

 

 

 

Power on test failure

 

 

 

Three abnormal reboots in

 

 

 

 

less than 20 minutes

 

 

 

Platform configured to enter

 

 

 

 

Failure mode consequent to

 

 

 

 

failure-induced reboot (this

 

 

 

 

is configurable using CLI

 

 

 

 

command)

 

 

 

Note Depending on the cause

 

 

 

 

of failure, the

 

 

 

 

management interface

 

 

 

 

and the platform

 

 

 

 

configuration may or

 

 

 

 

may not be

 

 

 

 

active/available.

 

 

 

 

 

 