Connect the Management Interface

Chapter 4 Connect the Management Interfaces and Perform Initial System Configuration

Connect the Management Interface

Data collection for the system configuration is completed.

Would you like to view the new configuration before it is applied? [yes/no]:

Apply and Save this configuration? [yes/no]: n

The changes you have just entered would be discarded, are you sure? [yes/no]:y

Setup procedure aborted, no configuration changes made.

Connect the Management Interface

Figure 4-2 Cabling the Management Port

PWR A

PWR B

STATUS

 

MNG 1

 

 

MNG 2

 

 

 

 

 

 

CONSOLE

 

LINK/

 

 

 

 

 

AUX

ACTIV

00

/

LINK/

10/100/

 

 

 

 

AC

 

 

 

 

 

 

 

TIVE 1000

 

 

1

2

3

LINK RX

TX

LINK RX

 

 

 

 

TX

RX

MM

TX

 

 

 

 

RX

MM

 

 

 

 

TX

 

 

 

 

 

SUB

GBE-1

 

 

 

 

LINE

 

 

 

 

 

NET

 

 

 

 

Cisco

 

 

 

 

 

SCE

 

 

 

 

 

2000

LINK RX

 

4xGBE

TX

LINK RX

 

 

 

 

TX

RX

MM

TX

 

 

 

 

RX

MM

 

 

 

 

TX

 

 

 

 

 

SUB

GBE-2

 

 

 

 

 

 

 

 

 

LINE/CASCADE NET

 

 

Series

92791

Note By default, the management port is configured to auto-negotiation enabled.

The SCE 1000 has two management ports, labeled Mng1 and Mng 2. Use the Mng 1 port.

Step 1 Plug the Ethernet cable provided (with attached RJ-45 connector) into the Mng 1 port on the front panel of the SCE 1000.

Step 2 Connect the other end of the Ethernet cable into your management network.

The Link LED on the SCE 1000 management port should light up.

Step 3 Test connectivity. From the host that you intend to use for remote management, ping to the SCE 1000 by typing ping and the SCE 1000 IP address, and pressing Enter (see the example, below).

This verifies that an active connection exists between the specified station and the management port.

EXAMPLE:

The following example displays a typical ping response where the target IP address is 10.1.1.201.

C:\>ping 10.1.1.201 pinging 10.1.1.201 ...

PING 10.1.1.201: 56 data bytes

64bytes from host (10.1.1.201): icmp_seq=0. time=0. ms

64bytes from host (10.1.1.201): icmp_seq=1. time=0. ms

64bytes from host (10.1.1.201): icmp_seq=2. time=0. ms

64bytes from host (10.1.1.201): icmp_seq=3. time=0. ms

----10.1.1.201 PING Statistics----

4packets transmitted, 4 packets received, 0% packet loss round-trip (ms) min/avg/max = 0/0/0