Cisco Systems manual SFS 7012 Component LEDs, Verifying Start-up, Chassis Status LED

Models: SFS 7012

1 116
Download 116 pages 14.21 Kb
Page 52
Image 52
Verifying Start-up

Chapter

md5 values match! 11088736

Starting at 0x80010000...

sysI

REGS BOOT

Initializing HyperTransport bus

HyperTransport initialization completed

Found Intel Strata Flash 128 MBit (0x8918).

Mounted raw file system on device /image1. (size=6291456 bytes)

Mounted raw file system on device /image2. (size=6291456 bytes)

Mounted raw file system on device /dump0. (size=1048576 bytes)

Mounted flash file system on device /rfa1. (size=2097152 bytes) Network configuration requested.

cliEnabled=1

sbe0 speed=100 fullDuplex=0 flowControl=0 sbe1 speed=100 fullDuplex=1 flowControl=0

Note The command spineip changes the IP address for image1 and image2,

Verifying Start-up

The following are ways to determine that the system has started successfully:

The IB link status indicator LEDs are lit up on the switch ports which are connected to an IB host.

The user is able to bring up the Chassis Viewer through a web browser on the OOB LAN. The home page displays the front and back views of the SFS 7012 switch.

SFS 7012 Component LEDs

Chassis Status LED

The chassis status LED is Green when the system is functioning normally.

The chassis status LED is Amber when one of the following conditions exists:

The system ambient temperature exceeds 52 C but remains less than 60 C.

Any Fan Alarm is amber.

Any power supply AC OK LED is off.

Any power supply DC OK LED is off

Any spine module Attention LED is on, or it has been determined that a spine is not functioning (even if it is unable to light the LED).

Any leaf module Attention LED is on, or it has been determined that a leaf is not functioning (even if it is unable to light the LED).

The chassis status LED is Red when the system can no longer function properly and indicates one of the following conditions:

The system ambient temperature exceeded 60 degrees C.

No functional fan trays are present.

No functional spines are present.

No functional leaves are present.

Cisco SFS 7012 InfiniBand Server Switch Hardware Users Guide

34

OL-8787-04

 

 

Page 52
Image 52
Cisco Systems manual SFS 7012 Component LEDs, Verifying Start-up, Chassis Status LED