Chapter

Note If the spine module RS-232 port is connected to a terminal emulation program, the user will be able to view the switch boot process. Be certain to use a null-modem/crossoverserial cable for the console port. The settings for the terminal emulation device should be:

8 data bits

no parity bits

1 stop bit

56K baud

Use VT100 emulation.

Flow control = XON/XOFF

Figure 2-14 SFS 7012 RS-232 Connector

(Unmanaged)

 

Fan

 

 

 

2 (Managed)

 

3

 

 

1 (Managed)

 

Spine Module

 

 

 

 

 

 

RS-232 Port

PS

PS

PS

Fan

1

3

2

1

 

Step 3 Verify the IP address with the command line interface (CLI) command showChassisIpAddr command. The system returns the information similar to the following:

Chassis IP Address: 192.168.100.9 Net mask: 0xffffff00

Changing the SFS 7012 IP Address and Default Gateway via the CLI

The CLI can be accessed via Telnet, SSH, or through the SFS 7012 RS232 serial ports.

Step 1 Connect null-modem/crossover serial cables to the RS-232 ports of the SFS 7012. If using a terminal emulation device, the settings should be:

8 data bits

no parity bits

1 stop bit

56K baud

Use VT100 emulation.

Flow control = XON/XOFF

Cisco SFS 7012 InfiniBand Server Switch Hardware Users Guide

30

OL-8787-04

 

 

Page 48
Image 48
Cisco Systems SFS 7012 manual Unmanaged Fan Managed