Chapter

Figure 2-11 SFS 7012 Chassis Front View

Figure 2-12 SFS 7012 Chassis Back View

 

Leaf 11

Leaf 12

Leaf 9

Leaf 10

Leaf 7

Leaf 8

Leaf 5

Leaf 6

Leaf 3

Leaf 4

Leaf 1

Leaf 2

AC power inlet for power

supplies 1 to 3

AC power inlet for power

supplies 4 to 6

RJ-45 for Spine 1

RJ-45 for Spine 2

Step 1 Connect a Category 5 or 6 (Cat 5/6) Ethernet cable to one of the RJ-45 connectors on the SFS 7012. Connect the other end of the Cat 5/6 to the OOB LAN workstation. Refer to Figure 2-12for which RJ-45 connector(s) to use:

Step 2 Connect the switch to IB-enabled hosts using 4X-to-4X IB cables.

Note Make sure all cables latch securely into the corresponding port connectors. If the IB cable connector is not properly oriented to fit onto the port receptacle (i.e., while attempting to insert the cable in the port), do not twist the connector to achieve the correct orientation. Instead, reach back a few feet on the cable, and twist the bulk cable to allow the connector to rotate to the proper orientation. Doing this prevents all of the rotational forces from acting right at the connector terminations.

Caution It is important to provide strain relief for the IB cable connector.

Cisco SFS 7012 InfiniBand Server Switch Hardware Users Guide

28

OL-8787-04

 

 

Page 46
Image 46
Cisco Systems SFS 7012 manual Leaf