Fault Messages and Error Codes | |
|
|
Error | Advisory Message | Description | Fault | Recommended Action | |
Code |
|
| Classification |
|
|
(Hex) |
|
|
|
|
|
|
|
|
|
|
|
0083 | MAX I/O CABLES | The maximum number of expansion | • | Reconfigure the expansion I/O system so | |
| EXCEEDED | I/O cables allowed was exceeded. |
|
| that it has an allowable number of cables. |
|
|
|
| • | Cycle power. |
|
|
|
|
|
|
0084 | MAX I/O POWER | The maximum number of expansion | • | Reconfigure the expansion I/O system so | |
| SUPPLIES EXCEEDED | I/O power supplies allowed was |
|
| that it has the correct number of power |
|
| exceeded. |
|
| supplies. |
|
|
|
|
|
|
0085 | MAX I/O MODULES | The maximum number of expansion | • | Reconfigure the expansion I/O system so | |
| EXCEEDED | I/O modules allowed was exceeded. |
|
| that it has an allowable number of |
|
|
|
|
| modules. |
|
|
|
| • | Cycle power. |
|
|
|
|
|
|
xx86(1) | EXPANSION I/O | An expansion I/O module could not | • | Change the baud rate in the user program | |
| MODULE BAUD RATE | communicate at the baud rate |
|
| I/O configuration, and |
| ERROR | specified in the user program I/O |
| • | |
|
| configuration. |
|
| the Run mode, or |
|
|
|
| • | Replace the module. |
|
|
|
| • | Cycle power. |
|
|
|
|
|
|
xx87(1) | I/O CONFIGURATION | • The expansion I/O configuration | • | Either correct the user program I/O | |
| MISMATCH | in the user program did not match |
|
| configuration to match the actual |
|
| the actual configuration, or |
|
| configuration, or |
|
| • The expansion I/O configuration |
| • | With power off, correct the actual I/O |
|
| in the user program specified a |
|
| configuration to match the user program |
|
| module, but one was not found, |
|
| configuration. |
|
| or |
|
|
|
|
| • The expansion I/O module |
|
|
|
|
| configuration data size for a |
|
|
|
|
| module was greater than what |
|
|
|
|
| the module is capable of holding. |
|
|
|
|
|
|
|
|
|
xx88(1) | EXPANSION I/O | The number of input or output image | • | Correct the user program I/O configuration | |
| MODULE | words configured in the user |
|
| to reduce the number of input or output |
| CONFIGURATION | program exceeds the image size in |
|
| words, and |
| ERROR | the expansion I/O module. |
| • | |
|
|
|
|
| the Run mode. |
|
|
|
|
|
|
xx89(1)(2) | EXPANSION I/O | An expansion I/O module generated | • | Refer to the I/O status file. | |
| MODULE ERROR | an error. |
| • | Consult the documentation for your |
|
|
|
|
| specific I/O module to determine possible |
|
|
|
|
| causes of a module error. |
|
|
|
|
|
|
xx8A(1)(2) | EXPANSION I/O | • Either an expansion I/O cable is | • | Correct the user program to eliminate a | |
| CABLE | configured in the user program, |
|
| cable that is not present |
| CONFIGURATION | but no cable is present, or |
| • | |
| MISMATCH ERROR | • an expansion I/O cable is |
|
| the Run mode, or |
|
| configured in the user program |
| • | Add the missing cable. |
|
| and a cable is physically present, |
| • | Cycle power. |
|
| but the types do not match. |
| ||
|
|
|
|
| |
|
|
|
|
|
|
Basic 32 Loader Control | UGC007/0702 |