Fault Messages and Error Codes

D-7

 

 

Error

Advisory Message

Description

Fault

Recommended Action

Code

 

 

Classification

 

 

(Hex)

 

 

 

 

 

 

 

 

 

 

 

0083

MAX I/O CABLES

The maximum number of expansion

Non-User

Reconfigure the expansion I/O system so

 

EXCEEDED

I/O cables allowed was exceeded.

 

 

that it has an allowable number of cables.

 

 

 

 

Cycle power.

 

 

 

 

 

 

0084

MAX I/O POWER

The maximum number of expansion

Non-User

Reconfigure the expansion I/O system so

 

SUPPLIES EXCEEDED

I/O power supplies allowed was

 

 

that it has the correct number of power

 

 

exceeded.

 

 

supplies.

 

 

 

 

 

 

0085

MAX I/O MODULES

The maximum number of expansion

Non-User

Reconfigure the expansion I/O system so

 

EXCEEDED

I/O modules allowed was exceeded.

 

 

that it has an allowable number of

 

 

 

 

 

modules.

 

 

 

 

Cycle power.

 

 

 

 

 

 

xx86(1)

EXPANSION I/O

An expansion I/O module could not

Non-User

Change the baud rate in the user program

 

MODULE BAUD RATE

communicate at the baud rate

 

 

I/O configuration, and

 

ERROR

specified in the user program I/O

 

Re-compile, reload the program and enter

 

 

configuration.

 

 

the Run mode, or

 

 

 

 

Replace the module.

 

 

 

 

Cycle power.

 

 

 

 

 

 

xx87(1)

I/O CONFIGURATION

The expansion I/O configuration

Non-User

Either correct the user program I/O

 

MISMATCH

in the user program did not match

 

 

configuration to match the actual

 

 

the actual configuration, or

 

 

configuration, or

 

 

The expansion I/O configuration

 

With power off, correct the actual I/O

 

 

in the user program specified a

 

 

configuration to match the user program

 

 

module, but one was not found,

 

 

configuration.

 

 

or

 

 

 

 

 

The expansion I/O module

 

 

 

 

 

configuration data size for a

 

 

 

 

 

module was greater than what

 

 

 

 

 

the module is capable of holding.

 

 

 

 

 

 

 

 

 

xx88(1)

EXPANSION I/O

The number of input or output image

Non-User

Correct the user program I/O configuration

 

MODULE

words configured in the user

 

 

to reduce the number of input or output

 

CONFIGURATION

program exceeds the image size in

 

 

words, and

 

ERROR

the expansion I/O module.

 

Re-compile, reload the program and enter

 

 

 

 

 

the Run mode.

 

 

 

 

 

 

xx89(1)(2)

EXPANSION I/O

An expansion I/O module generated

Non-User

Refer to the I/O status file.

 

MODULE ERROR

an error.

 

Consult the documentation for your

 

 

 

 

 

specific I/O module to determine possible

 

 

 

 

 

causes of a module error.

 

 

 

 

 

 

xx8A(1)(2)

EXPANSION I/O

Either an expansion I/O cable is

Non-User

Correct the user program to eliminate a

 

CABLE

configured in the user program,

 

 

cable that is not present

 

CONFIGURATION

but no cable is present, or

 

Re-compile, reload the program and enter

 

MISMATCH ERROR

an expansion I/O cable is

 

 

the Run mode, or

 

 

configured in the user program

 

Add the missing cable.

 

 

and a cable is physically present,

 

Cycle power.

 

 

but the types do not match.

 

 

 

 

 

 

 

 

 

 

 

 

Basic 32 Loader Control

UGC007/0702