Service

Service

All service must be carried out by trained personnel in order to avoid personal injury or damage to the machine.

Changing the knives

Removing the knives

Check the screen for wear when the knives are changed. Change the screen when the holes begin to be pear shaped.

Be careful when handling the knives, they are sharp and can cause personal injury. Use protective gloves!

Each time the knives are changed, the knife fastening screws must be replaced by new ones.

Changing the knives.

A, B

Open the hopper and any door. Remove the granule bin, then fold the screen box down and lift it out – see Section 5.3.

Removing the rotating knives.

1Remove the screws (A) and washers (B),

2 each per knife. The knives are now loose.

2Lift out the rotating knives.

3Clean the surfaces where the knives were

located.

Removing the fixed knives.

4Undo the socket cap screws (C) on the front knife support rule (D).

NOTE: Hold the fixed knife and support rule before removing the last screw.

5Lift out the fixed knife together with the support rule.

6Clean the knife location.

7Put the support rule back loosely.

E FD C

7 - 2 l Service

Page 38
Image 38
Conair CHS-810 Service, Changing the knives, Removing the knives, Removing the rotating knives, Removing the fixed knives