Conair CHS-810 manual Operation and Daily Maintenance l 6

Models: CHS-810

1 88
Download 88 pages 42.76 Kb
Page 35
Image 35

Granulator with conveyor belt, if the conveyor belt does not start – check the conveyor belt overload circuit breaker.

The conveyor belt motor has an overload circuit breaker, F3, in the distribution box, which trips if you jam or overload the conveyor belt.

This is indicated in the window (A) which shows “0”. Reset, press the “Reset” button (B).

Check that there is no material left on the band before re-starting.

Check the granulator knives and knife tolerance.

If the granulator knives are blunt and unsharpened, or if the knife clearance is incorrect, this can result in stoppage. The granulator motor overload circuit breaker will trip. Check the knives.

Sharpen or replace the knives, or adjust the knife clearance, see next Section.

Check also the wiring diagram in Section 9; supplements and deviations may be applicable.

Operation and Daily

6

Maintenance

 

 

 

Operation and Daily Maintenance l 6 - 7

Page 35
Image 35
Conair CHS-810 manual Operation and Daily Maintenance l 6