Transmission (continued)

Transmission (continued)

B

A

V-belt Adjustment

Remove the upper panel on the right-hand side of the granulator.

CHS series-noise encapsulated machine, remove the rear guard

plate above the motor and open the door.

Undo and remove the extraction pipe.

Alt. CHS series-machine with extraction fan, undo the quick coupling on the outlet pipe stub.

Remove the granule bin.

Undo the motor screws (A) lightly, 4 pcs.

Adjust the belt tension by increasing/reducing the distance of the motor to the cutter pulley, using the motor adjustment screws (B), 2 pcs.

Tighten the motor screws (33.2lb-ft [45 Nm] torque)

If the belt tension is adjusted, the belt need to be re-checked after 20 - 30 hours at full load.

7 Service

S e r v i c e l 7 - 9

Page 45
Image 45
Conair CHS-810 manual Transmission continued, V-belt Adjustment, Service