Cornelius R-404A REFRIGERANT service manual Freeze Cylinders Manual or Automatic Defrost Systems

Models: R-404A REFRIGERANT

1 97
Download 97 pages 32.75 Kb
Page 36
Image 36

‘‘CO2 OUT’’ Fault Message.

‘‘CO2 OUT’’ fault message will appear on message display when CO2 supply to Unit has been turned off or if CO2 pressure drops below 50-psi. A minimum CO2 pressure of 75-psi must be available to Unit to extinguish ‘‘CO2 OUT’’ fault message.

‘‘SYRUP 1’’ or ‘‘SYRUP 2’’ Fault Messages.

‘‘SYRUP 1’’ or ‘‘SYRUP 2’’ fault messages will appear on message display if product tanks are not connected to Unit or product tanks are empty. Syrup systems syrup float switches must be filled with syrup to extinguish ‘‘SYRUP 1’’ or ‘‘SYRUP 2’’ fault messages.

‘‘DEFROST 1’’ or ‘‘DEFROST 2’’ Display Messages.

‘‘DEFROST 1’’ or ‘‘DEFROST 2’’ display messages will appear on message display if either freeze cylinder is in defrost mode. ‘‘DEFROST 1’’ or ‘‘DEFROST 2’’ messages will remain on during defrost cycle and will disappear when cycle has ended.

‘‘POINT OF SALE’’ Display Message.

Three ‘‘POINT OF SALE‘’ display messages are available to choose from and may be programmed into Unit as instructed to appear on message display.

Common Outlet Temperatures.

Evaporator refrigeration coils inlet 1 and inlet 2 and common outlet temperatures may be displayed on control panel message display as instructed.

FREEZE CYLINDERS MANUAL OR AUTOMATIC DEFROST SYSTEMS

The Unit is equipped with both manual and automatic hot-gas defrost systems. The automatic defrost system may be programmed into the Unit to occur up to nine different times a day with a minimum of two hours between defrost time settings or the system may be completely turned off.

MANUAL DEFROST SYSTEM

The manual hot-gas defrost system may be activated at any time by pressing ‘‘DEFROST’’ switch on front of the Unit. Refrigeration compressor will operate for a short time, then both freeze cylinders will go into defrost and defrost for approximately 60-seconds. At end of manual defrost cycle, Unit will return to normal operation. Manual defrost may be cancelled at any time by pressing ‘‘CANCEL DEFROST’’ switch.

AUTOMATIC DEFROST SYSTEM

The automatic hot-gas defrost system may be programmed into the Unit to occur up to nine different times a day with a minimum of two hours between defrost settings. At start of each automatic defrost cycle, refrigeration compressor will operate for 30 seconds to pump freon out of freeze cylinders evaporator coils. After freon has been pumped out of freeze cylinders evaporator coils, No. 1 freeze cylinder only will go into defrost for approxi- mately 7 minutes and then will return to normal operation. This ends automatic defrost cycle of No. 1 freeze cyl- inder. No. 2 freeze cylinder will defrost 30 minutes after the start of No. 1 freeze cylinder. The next automatic defrost cycle will occur according to time programmed into the Unit.

29

312028000

Page 36
Image 36
Cornelius R-404A REFRIGERANT service manual Freeze Cylinders Manual or Automatic Defrost Systems, Manual Defrost System