Carbonator Secondary CO2 Regulator.

(see Figure 2 and 6)

1.Remove the Unit lower front access panel as instructed for access to the carbonator(s) secondary CO2 regulator(s).

IMPORTANT: The carbonator tank secondary CO2 regulator must be adjusted 25-psi higher or more above the product blender tanks secondary CO2 regulators pressure settings. The carbonated water and syrup pressures must be able to overcome and vent the product blender tanks head pressures while the tanks are filling with carbonated water and syrup. Carbonator tank secondary CO2 regulator not adjusted high enough will cause a decreased flow of carbonated water into the blender tanks, which will increase brix of the dispensed product.

2.Adjust carbonator(s) secondary CO2 regulator(s), with 100-psi gauge(s), by turning regulator(s) adjusting screw(s) to the right (clockwise) until gauge(s) reads 50 to 60-psig.

3.Install the lower front access panel by reversing the removal procedure.

ADJUSTING BRIX (WATER-TO-SYRUP) ‘‘RATIO’’ OF DISPENSED PRODUCT

(see Figures 2 and 6)

1.Remove Unit lower front access panel as instructed for access to product blender tanks secondary CO2 regulators and product sample valves.

2.Check product blender tanks secondary CO2 regulators, with 60-psi gauges, for proper pressure settings which is set at 25 to 30-psi for best textured dispensed product. If adjustment is necessary, adjust as instructed.

3.Remove both Unit side panels as instructed for access to product shutoff valves located close to product blender tanks.

4.Close product shutoff valve in line between applicable product blender tank and associated freeze cylinder brix adjustment will be performed on.

5.Press applicable ‘‘FILL 1’’ or ‘‘FILL 2’’ switch to prevent more product from filling product blender tank.

6.Open applicable product blender tank product sample valve and take sample (approximately 6-ounces) of product in cup.

NOTE: Temperature compensated hand-type refractometers (P/N 511004000) are available from the Cor- nelius Company.

7.Observe pressure setting on carbonator secondary CO2 regulator gauge.

8.Press applicable ‘‘AUTO BLEND 1‘’ or ‘‘AUTO BLEND 2’’ switch to fill product blender tank 1/4-full of new batch of product. When product blender tank is 1/4-full of product, press applicable ‘‘FILL 1’’ or ‘‘FILL 2’’ switch to prevent more product from entering product blender tank.

9.Repeat steps 6 and 7 preceding to check product sample for brix.

10.Repeat steps 7 through 10 preceding until proper brix adjustment is achieved.

11.Open product shutoff valve in line between product blender tank and freeze cylinder.

12.Press applicable ‘‘AUTO BLEND 1’’ or ‘‘AUTO BLEND 2’’ switch.

13.Install Unit side panels and lower front access panel by reversing removal procedures.

312028000

48

Page 55
Image 55
Cornelius R-404A REFRIGERANT service manual Adjusting Brix WATER-TO-SYRUP ‘‘RATIO’’ of Dispensed Product