Trouble

Probable Cause

Remedy

MANUAL DEFROST CYCLE

E. Master circuit board not

E. Replace master circuit board.

DOES NOT OPERATE WHEN

operating properly.

 

‘‘DEFROST’’ SWITCH IS

 

 

PRESSED. (cont’d)

 

 

 

 

 

DEFROST CYCLE DOES NOT A.

Flat cable not properly

CANCEL AFTER PRESSING

connected to control switch

‘‘CANCEL DEFROST ’’

module or master circuit

SWITCH.

board.

A.Properly connect flat cable to control switch module or master circuit board.

B.Flat cable connected between control switch module and master circuit board pinched and shorted out or broken wire in cable.

B.Check cable for pinched or broken wire condition and repair or replace as necessary.

C.Inoperable ‘‘CANCEL DEFROST’’ switch on control panel switch module.

C.Replace control panel switch module.

D. Master circuit board not

D.

Replace master circuit board.

 

operating properly.

 

 

 

TROUBLESHOOTING PRODUCT BLENDER TANKS AND CARBONATOR

 

 

 

CARBONATOR WATER PUMP A.

No electrical power to Unit.

A. Connect electrical power to Unit.

MOTOR WILL NOT OPERATE.

 

 

Check power source.

B.

‘‘AUTO BLEND 1’’ or ‘‘AUTO

B.

Press ‘‘AUTO BLEND 1’’ or

 

BLEND 2’’ switches have not

 

‘‘AUTO BLEND 2’’ switch.

 

been pressed.

 

 

C.‘‘H2O OUT’’ fault message is on.

C.Restore water supply to Unit.

D.‘‘CO2 OUT’’ fault message is on.

E.Loose or broken electrical wires.

D.Replenish CO2 supply as instructed.

E.Tighten connections or replace wires.

F. Overheated water pump motor F. cut off by overload protector.

Check for proper line voltage. Check restricted pump discharge.

G.Binding water pump (new or replacement pump only).

G.Remove water pump from motor. Rotate pump coupling shaft 180 degrees, then reinstall pump.

H.

Inoperative water pump and/or

H.

Replace pump and/or motor.

 

motor.

 

 

I.

Inoperative carbonated water

I.

Replace level control switches.

 

tank level control switches.

 

 

J.Binding, damaged, or dirty carbonated water tank balance mechanism.

J.Clean, repair, or replace balance mechanism.

K. Inoperative water pump and/or K.

Replace water pump and/or

motor.

motor.

 

 

312028000

66

Page 73
Image 73