REPLENISHING CO2 SUPPLY
WARNING: CO2 displaces oxygen. Strict attention must be observed in the prevention of CO2 (carbon dioxide) gas leaks in the entire CO2 and soft drink system. If a CO2 gas leak is suspected, particularly in a small area, immediately ventilate the contaminated area before
attempting to repair the leak. Personnel exposed to high concentration of CO2 gas will experience tremors which are followed rapidly by loss of consciousness and suffocation.
NOTE: When indicator on primary CO2 cylinder regulator assembly
1.Fully close (clockwise) CO2 cylinder valve.
2.Slowly loosen CO2 regulator assembly coupling nut allowing CO2 pressure to escape, then remove regula- tor assembly from empty CO2 cylinder.
3.Unfasten safety chain and remove empty CO2 cylinder.
4.Position full CO2 cylinder and secure with safety chain.
WARNING: To avoid personal injury and/or property damage, always secure CO2 cylinder in upright position with safety chain to prevent it from falling over. Should valve become accidentally damaged or broken off, CO2 cylinder can cause serious personal injury.
5.Make sure gasket is in place inside CO2 regulator coupling nut, then install regulator on CO2 cylinder.
6.Open (counterclockwise) CO2 cylinder valve slightly to allow lines to slowly fill with gas, then open valve fully to
7.Check CO2 connections for leaks. Tighten loose connections.
SYRUP FLAVOR CHANGE
One or both syrup flavors can be changed at the same time. Perform flavor change on one system as follows:
1.Perform sanitizing procedure on syrup system. Syrup flavor change will be made as instructed in the
SERVICE AND MAINTENANCE SECTION.
IMPORTANT: The following CO2 and liquid disconnects disconnecting and connecting procedure for soft drink tank replacement or filling soft drink tank in place must be performed in order as follows:
2.To disconnect soft drink tank from Unit syrup system.
A.Disconnect liquid disconnect from soft drink tank. NOTE - Disconnecting liquid disconnect from soft drink tank first prevents syrup from backflowing through Unit syrup flow regulator, which may alter regulator adjustment.
B.Second, disconnect CO2 quick disconnect from soft drink tank.
3.To connect soft drink tank into Unit syrup system.
A.First, connect CO2 quick disconnect to soft drink tank to pressurize tank.
B.Second, connect liquid quick disconnect to soft drink tank.
4.First, pressurize soft drink tank containing new flavor syrup by connecting CO2 line to tank, then connect Unit syrup inlet line to tank.
55 | 312028000 |