Trouble

 

Probable Cause

 

Remedy

ALL FAULT MESSAGE NOT

D.

Master circuit board not

D.

Replace master circuit board.

OPERATING (cont’d)

 

operating.

 

 

 

E.

Fault message display module

E.

Replace fault message display

 

 

not operating properly.

 

module.

 

 

 

 

 

‘‘CO2 OUT’’ FAULT MESSAGE

A.

CO2 supply turned off or

A.

Open CO2 cylinder shutoff valve

GOES ON DURING

 

exhausted.

 

or replenish CO2 supply as

OPERATION.

 

 

 

instructed.

 

B.

Primary CO2 regulator set too

B.

Adjust primary CO2 regulator as

 

 

low.

 

instructed.

 

C.

Inoperable CO2 pressure

C.

Replace CO2 pressure switch.

 

 

switch.

 

 

 

 

 

 

 

‘‘H2O OUT’’ FAULT MESSAGE

A.

Water supply turned off or

A.

Turn on water supply or check

GOES ON DURING

 

water pressure inadequate.

 

water supply line pressure.

OPERATION.

 

 

 

 

 

B.

Plugged water filter or water

B.

Change water filter or clean water

 

 

pump strainer screen.

 

pump strainer screen as

 

 

 

 

instructed.

 

C.

Inoperative water pressure

C.

Replace water pressure switch.

 

 

switch.

 

 

 

 

 

 

 

‘‘SYRUP 1’’ OR ‘‘SYRUP 2’’

A.

Soft drink tank empty.

A.

Replenish syrup supply as

FAULT MESSAGE GOES ON

 

 

 

instructed.

DURING OPERATION.

 

 

 

 

 

 

 

 

 

‘‘ERROR 1’’ OR ‘‘ERROR 2’’

A.

Error within Unit has

A.

Locate and correct error, then

FAULT MESSAGE GOES ON

 

developed interrupting normal

 

press ‘‘ERROR RESET’’ switch to

DURING OPERATION.

 

operation.

 

restore normal operation.

 

 

 

 

 

FREEZE CYLINDER

A.

Loose or broken electrical

A.

Repair electrical wires.

AUTOMATIC DEFROST

 

wires.

 

 

CYCLE DOES NOT

 

 

 

 

OPERATE.

 

 

 

 

 

B.

Inoperable automatic defrost

B.

Replace master circuit board.

 

 

timer.

 

 

 

 

 

 

 

UNIT DOES NOT GO OFF

A.

Automatic defrost timer stuck

A.

Replace master circuit board.

AUTOMATIC DEFROST

 

in automatic defrost cycle.

 

 

CYCLE.

 

 

 

 

 

 

 

 

 

MANUAL DEFROST CYCLE

A.

Flat cable not properly

A.

Properly connect flat cable to

DOES NOT OPERATE WHEN

 

connected to control switch

 

control switch module or master

‘‘DEFROST’’ SWITCH IS

 

module or master circuit

 

circuit board.

PRESSED.

 

board.

 

 

 

B.

Flat cable connected between

B.

Check cable for pinched or

 

 

control switch module and

 

broken wire condition and repair

 

 

master circuit board pinched

 

or replace as necessary.

 

 

and shorted out or broken wire

 

 

 

 

in cable.

 

 

 

C.

Inoperable ‘‘DEFROST’’ switch

C. Replace control panel switch

 

 

on control panel switch

 

module.

 

 

module.

 

 

 

D.

Loose or broken wire.

D.

Repair wire.

 

 

 

 

 

65