5.Press applicable ‘‘FILL 1’’ or ‘‘FILL 2’’ switch to fill applicable No. 1 or No. 2 syrup system syrup float switch with syrup.

6.Press applicable ‘‘AUTO BLEND 1’’ or ‘‘AUTO BLEND 2’’ switch to fill applicable No. 1 or No. 2 system product blender tank with product.

7.Press applicable ‘‘AUTO 1’’ or ‘‘AUTO 2’’ switch to start refrigeration system and beater in applicable No. 1 or No. 2 freeze cylinder.

CAUTION: Do not relieve freeze cylinder pressure too fast or product will foam excessively in freeze cylinder and lose carbonation.

8.After carbonator water pump cycles off, intermittently pull and release applicable No. 1 or No. 2 freeze cyl-

inder faceplate relief valve. This bleeds CO2 from freeze cylinder and allows product to enter and fill cylin- der.

9.If necessary, adjust BRIX, product viscosity (product consistency), and product carbonation of dispensed product as instructed.

CLEANING CO2 GAS CHECK VALVES

(see applicable Figures 2 and 13)

The CO2 gas check valves must be inspected and serviced at least once a year under normal conditions and after any servicing or disruption of the CO2 system. ALWAYS REPLACE QUAD RING SEAL EACH TIME GAS CHECK VALVES ARE

SERVICED.

QUAD RING 183294000

BALL 183296000

SPRING 183297000

RETAINER 183298000

BODY 183295100

QUAD RING SEAL MUST BE REPLACED

EACH TIME CHECK VALVE IS SERVICED.

FIGURE 13. CO2 GAS CHECK VALVE

REPLACING FREEZE CYLINDER BEATER DRIVE MOTOR

(see Figures 5 and 9)

IMPORTANT: Note in 6 “MOTOR SELECT” the number of freeze cylinder beater drive motors manufacturers that are listed. Your Unit was manufactured and equipped with freeze cylinder beater drive motors from one of these manufacturers. The replacement freeze cylinder beater drive motor is also manufactured by one of these manufacturers listed. WHEN REPLACING ONE OF THE BEATER MOTORS, NOTE THE MANUFACTURER’S NAME ON THE MOTOR. THE BEATER MOTOR MANUFACTURER’S NAME MUST BE PROGRAMMED INTO THE UNIT WHICH WILL MATCH THE MOTOR TO THE UNIT ELECTRONICS. Proceed as follows to replace the freeze cylinder beater drive motor.

57