Locate the Unit so the following requirements are satisfied.

1. Close to a filtered plain water inlet supply line with a minimum water pressure of 12-psig.

NOTE: The FCB Dispenser refrigeration system is equipped with a condenser coil that is cooled by two condenser coil fans. Circulating air, required to cool the refrigeration system’s condenser coil, is drawn in through the grilled panel on the right-hand side and is exhausted out through the opposite side grilled panel. Restricting air circulation through the Unit will decrease its cooling efficiency.

2.When installing Unit in it’s operating position, do not allow obstructions to block sides, top, and front of the Unit which will block off cooling air intake to the inside of the Unit. Air flow through the Unit must be present to provide adequate cooling for the refrigeration system.

CAUTION: Do not place or store anything on top of the Unit.

Locate the Unit to provide the following clearances:

Top of Unit

Open (24-inches min.)

Back side

0-inches

Sides

6-inches (min)

Front

Open

INSTALLING UNIT

CAUTION: This Unit is intended for indoor installation only. Do not install this Unit in an outdoor environment which would expose it to the outside elements.

IMPORTANT: After Unit has been placed in operating position, make sure it is sitting in a level position on a surface that provides adequate support and stability.

INSTALLING LEVELING LEGS

Very carefully, tilt Unit up and install LEVELING LEGS (item 13) on four corners of the Unit base.

INSTALLING DRIP TRAY SUPPORTS (ITEM 7) AND (ITEM 8)

1.Install DRIP TRAY SUPPORT, LEFT (item 7) and DRIP TRAY SUPPORT, RIGHT (item 8) on front of the Unit and secure with SCREWS (item 6). See Figure 5.

2.Place DRIP TRAY (item 9) on drip tray supports.

3.Place CUP REST (item 5) in drip tray.

INSTALLING DRIP TRAY DRAIN HOSE KIT (ITEM 10)

Install DRIP TRAY DRAIN HOSE KIT (item 10) on Unit as instructed in Installation Instructions provided with the Kit.

PREPARING UNIT FOR CONNECTION TO SYRUP, CO2, AND CITY PLAIN WATER SOURCES

Route coiled up syrup, CO2, and plain water lines out through the hole provided in the Unit base.

312028000