INSTALLATION

This section covers unpacking and inspection, installing Loose-Shipped Parts, selecting location, installing Unit, preparing for operation, and operation.

UNPACKING AND INSPECTION

(see Figure 5)

NOTE: The Unit was thoroughly inspected before leaving the factory and the carrier has accepted and signed for it. Any damage or irregularities should be noted at time of delivery (or not later than 15 days from date of delivery) and immediately reported to the delivering carrier. Request a written inspection report from a Claims Inspector to substantiate any necessary claim. File claim with the delivering carri- er, not with IMI Cornelius Inc.

1.After Unit has been unpacked, remove shipping tape and other packing material.

2.Remove Unit sides and back panels as instructed.

3.Remove shipping bolts that secure Unit to skid, then remove skid.

4.Unpack Loose-Shipped Parts. Make sure all items are present and in good condition.

Table 3. Loose-Shipped Parts

Item

 

 

 

No.

Part No.

Name

Qty.

 

 

 

 

1

178025100

Tapered Gasket, White

4

 

 

 

 

2

322859000

Spanner Wrench, Dispensing Valve

1

 

 

 

 

3

325216000

Cleaning Brush

1

 

 

 

 

4

311304000

Tapered Gasket, Black

1

 

 

 

 

5

317660000

Cup Rest

1

 

 

 

 

6

325282000

Thread Cutting Screw, Hex Hd.; No. 8 by 18 by 1/2-in. long

2

 

 

 

 

7

2738

Drip Tray Support, Left

1

 

 

 

 

8

2739

Drip Tray Support, Right

1

 

 

 

 

9

317659029

Drip Tray

1

 

 

 

 

10

326002000

Kit, Drip Tray Drain Hose

1

 

 

 

 

11

2899

Wrench, Rear Seal Housing

1

 

 

 

 

12

3810

Tool, Drive/Coupler Adjustment Gauge

1

 

 

 

 

13

324252000

Leveling Leg

4

 

 

 

 

14

3247

Spacer, White

2

 

 

 

 

15

3221

Front Access Panel

1

 

 

 

 

16

3108

Thread Cutting Screw, Phil Pan Hd; No. 10 by 32 by 1-in. long

2

 

 

 

 

IDENTIFICATION OF LOOSE-SHIPPED PARTS

1.Tapered gaskets, white (item 1) are used to seal connections when connecting Unit product inlet lines to product tanks and connecting Unit CO2 inlet line to CO2 source.

2.Spanner wrench, dispensing valve (item 2) is used to remove shank nuts securing dispensing valves to faceplates.

312028000

7

Page 14
Image 14