Cornelius R-404A REFRIGERANT Opening and Closing Front Access Door, Front Access Panel

Models: R-404A REFRIGERANT

1 97
Download 97 pages 32.75 Kb
Page 45
Image 45

FRONT ACCESS PANEL

Remove two screws securing front access panel, then remove panel and plastic spacers from the Unit. MAKE SURE WHEN REINSTALLING THE FRONT ACCESS PANEL, TO REINSTALL THE PLASTIC SPACERS IN BETWEEN THE PANEL AND THE UNIT FRAME.

OPENING AND CLOSING FRONT ACCESS DOOR

OPENING FRONT ACCESS DOOR

Using a flat blade screwdriver, turn lock counterclockwise to unlock the front access door (see Figure 5), then open the door.

CLOSING FRONT ACCESS DOOR

Close front access door, then use a flat blade screwdriver to turn lock clockwise to lock the door.

LUBRICATION

CARBONATOR WATER PUMP MOTOR

(see Figure 12)

Carbonator water pump motor bearings must be lubricated periodically. Refer to oiling instructions on motor. DO NOT OVER OIL.

SERVICING DISPENSING VALVES CAGED O-RINGS AND FREEZE CYLINDERS DRIVE SHAFT/ SEAL ASSEMBLIES

Servicing Dispensing Valves Caged O-Rings.

(see Figure 7)

NOTE: Dispensing valves caged O-Rings should be serviced (lubricated) every six months and O-Rings should be replaced once a year.

1.Defrost freeze cylinders, shut Unit down, disconnect electrical power from Unit, close product shutoff valves in lines leading from the product blender tanks to the freeze cylinders, then drain product from the freeze cylinders.

NOTE: Item numbers in parentheses in this paragraph are in reference to Figure 8.

2.Remove HEX NUTS (item 7) and FLATWASHERS (item 6) securing FACEPLATE (item 8) to freeze cylin- der, then remove faceplate from

cylinder.

312028000

38

 

Page 45
Image 45
Cornelius R-404A REFRIGERANT Opening and Closing Front Access Door, Front Access Panel, Opening Front Access Door