ITEMS AFFECTED BY ERROR

 

 

 

 

 

 

 

 

MESSAGE

 

BEATER

BEATER

REFRIG 1

 

REFRIG 2

DISPLAYED

ERROR

MOTOR 1

MOTOR 2

 

Motor 1

Low Current, < 109,

OFF

 

OFF

 

 

 

Sensed on Motor One

 

 

 

 

 

 

 

 

 

 

 

 

Motor 2

Low Current, < 109,

 

OFF

 

 

OFF

 

Sensed on Motor Two

 

 

 

 

 

 

 

 

 

 

 

 

Motor 1

High Current > 255,

OFF

 

OFF

 

 

 

Sensed on Motor One

 

 

 

 

 

 

 

 

 

 

 

 

Motor 2

High Current > 255,

 

OFF

 

 

OFF

 

Sensed on Motor Two

 

 

 

 

 

 

 

 

 

 

 

 

REFRIG

**Maximum Run Time on Compressor

OFF

OFF

OFF

 

OFF

 

 

 

 

 

 

 

SYRUP 1

Syrup Out Side One

 

 

OFF

 

 

 

 

 

 

 

 

 

SYRUP 2

Syrup Out Side Two

 

 

 

 

OFF

 

 

 

 

 

 

 

CO2 OUT

CO2 Out

 

 

OFF

 

OFF

 

 

 

 

 

 

 

H2O

H2O Out

 

 

*OFF

 

*OFF

 

 

 

 

 

 

 

SENSOR 1

Temp Sensor Inlet One

OFF

OFF

OFF

 

OFF

 

 

 

 

 

 

 

SENSOR 2

Temp Sensor Inlet Two

OFF

OFF

OFF

 

OFF

 

 

 

 

 

 

 

SENSOR 3

Temp Sensor Outlet

OFF

OFF

OFF

 

OFF

 

 

 

 

 

 

 

*The refrigeration system and carbonator shall continue to operate for 1.5 minutes after a water pressure loss has been detected. If water pressure loss continues beyond 1.5 minutes, the refrigeration system and carbonator will stop.

**25 minutes on Standard System, 30 minutes on Remote System.

TABLE 9 DISPLAYED ERROR CONDITIONS

3.Press “CANCEL DEFROST” (ADVANCE) switch. The motor manufacturer’s name will start blinking.

4.Press the “CANCEL DEFROST” (ADVANCE) switch again, which will change to another blinking manufac- turer’s name.

5.Keep pressing and releasing the “CANCEL DEFROST” (ADVANCE) switch until the applicable blinking manufacturer’s name appears on the message display. This indicates manufacturer’s name of the No. 1 freeze cylinder beater motor (new Unit installation) or the new installed replacement motor.

6.After the applicable beater motor manufacturer’s name has been selected, press “DEFROST” (SELECT) switch which will match the beater motor to the Unit electronics. The motor manufacturer’s name will no longer be blinking.

7.Press “DEFROST” (SELECT) switch to return to “MOT_MFG1”.

8.Press “CANCEL DEFROST” (ADVANCE) switch to go from “MOT_MFG1” to “MOT_MFG2” (represents No. 2 freeze cylinder beater motor) which will appear on the message display.

9.Repeat steps 2 through 6 to program in the correct beater motor manufacturer’s name for No. 2 freeze cylinder.

PROGRAMMING PROPER REFRIGERANT TYPE INTO UNIT ELECTRONICS

The Dispenser electronics must be programmed for the proper refrigeration pulse rate according to the type of refrigerant gas that has been installed in the refrigeration system. Note Dispenser serial plate for the type of re- frigerant gas that has been installed, then proceed as follows to program the Dispenser.

25

312028000

Page 32