electrical requirements

CONNECTING TO POWER SOURCE OUTLET

This machine must be grounded while in use to protect the operator from electric shock.

Plug power cord into a 120V properly grounded type outlet protected by a 15-amp. dual element time delay or Circuit- Saver fuse or circuit breaker.

If you are not sure that your outlet is properly grounded, have it checked by a qualified electrician.

WARNING: DO NOT PERMIT FtNGERSTO TOUCH THE

TERMINALS OF PLUGS WHEN INSTALLING OR RE-

MOVING THE PLUG TO OR FROM THE OUTLET.

WARNING: IF NOT PROPERLY GROUNDED THIS

POWER TOOL CAN INCUR THE POTENTIAL HAZARD OF ELECTRICAL SHOCK. PARTICULARLY WHEN USED IN DAMP LOCATIONS IN PROXIMITY TO PLUMBING. IF AN ELECTRICAL SHOCK OCCURS THERE IS THE

POTENTIAL OF A SECONDARY HAZARD SUCH AS YOUR HANDS CONTACTING THE ABRASIVE BELT

OR DISC.

If power cord is worn or cut, or damaged in any way, have it replaced immediately.

Your unit is wired for 120 volts and has a plug that looks like the one shown below.

3-PRONG PLUG

PROPERLY

GROUNDED /n Ul

OUTLETs, 4

/Do l GROUNDING

\/PRONG

This power tool is equipped with a 3-conductor cord and grounding type plug, approved by Underwriters' Labora-

tories and the Canadian Standards Association. The ground

conductor has a green jacket and is attached to the tool hous=

ing at one end and to the ground prong in the attachment plug at the other end.

This plug requires a mating 3-conducto{ grounded type out- let as shown.

If the outlet you are planning to Use for this power tool is

of the two prong type DO NOT REMOVE OR ALTER

THE GROUNDING PRONG IN ANY MANNER, Use an adapter as shown and always connect the grounding lug to known ground.

It is recommended that you have a qualified electrician replace the TWO prong outlet with a properly grounded THREE prong outlet.

A temporary adapter as shown below is available for connecting plugsto 2-prong receptacles. The green ground- ing lug extending from the adapter must be connected to a

permanent ground such as to a properly grounded outlet box,

A temporary adapter as illustrated is available for connecting

plugs to 2-prong receptacles. The temporary adapter should

be used only until a properly grounded outlet can be installed by a qualified electrician.

NOTE: The adapter illustrated is for use only if you already have a properly grounded 2-prong receptacle.

The use of any extension cord will cause some loss of

power. To keep this to a minimum and to prevent over-

heating and motor burn-out; use the table below to deter- mine the minimum wire size (A.W.G.) extension cord. Use

only 3 wire extension cords which have 3-prong grounding type plugs and 3-pole receptacles which accept the tools

plug.

GROUNDING LUG

 

 

I

_

 

MAKE

SURE

THIS

IS

3-PRONG

_

_

I _

" j}

CONNECTED

TO

A

__.,,,_r__..._3_

 

[_

]1

2-PR ONG

 

 

 

/

_

 

RECEPTACLE

 

ADAPTER

 

 

 

 

 

 

Extension Cord

Length

 

 

Wire

Size

A.W.G.

 

 

 

 

 

 

 

0-25Ft

...................

 

 

 

16

 

26-50Ft

...................

 

 

 

14

 

51-100

Ft

 

 

 

12

 

CHECK MOTOR ROTATION

Place the motor on your workbench or on the floor. Standing clear of the motor shaft, plug the motor cord into a properly grounded outlet. Notice the rotation of the shaft.

As you look directly at the motor shaft it should be turning in

the counterclockwise direction _ . tf the motor shaft is

turning counterclockwise, remove the plug from the power

outlet and continue the assembly procedures. If the motor is

turning clockwise, remove the plug from the power outlet and contact your Sears Store immediately,