Manufacturing Test Support, MTK
Table 6-1. Serial Command Protocol
Command | Command Description | ||
ST |
| START STANDARD TEST | |
Parameters | CL <power level> | CONFIGURE POWER LEVEL | |
PN <PN code> | CONFIGURE PN CODE INDEX | ||
| |||
| TT <tx error threshold> | CONFIGURE TX ERROR THRESHOLD | |
| RT <rx error threshold> | CONFIGURE RX ERROR THRESHOLD | |
Test | C1 <channel> | CONFIGURE CHANNEL | |
C2 <channel> | CONFIGURE SECOND CHANNEL | ||
Standard | |||
CB <# of bytes> | CONFIGURE NUMBER OF BYTES/PACKET PAYLOAD | ||
| C3 <channel> | CONFIGURE THIRD CHANNEL | |
|
|
| |
| CP <# of packets> | CONFIGURE NUMBER OF PACKETS | |
TC <time> | TRANSMIT CARRIER | ||
TR <time> | TRANSMIT RANDOM | ||
SC <channel> <PN code> | SET COMMUNICATION | ||
Note The device transmits on <channel> + 2. | |||
<power level> <correlator threshold> | |||
|
| For example, 2=2.402 GHz | |
PD <packet data> | SET PACKET DATA (ASCII representation of hexadecimal numbers | ||
without any prefix, i.e. 5A 34 CB) | |||
|
| ||
CA <crystal adjust> | SET CRYSTAL FREQUENCY ADJUST VALUE | ||
RE |
| RESTORE NVRAM DEFAULTS | |
CS |
| SHOW CURRENT CONFIGURATION | |
HE |
| SHOW HELP MENU |
Every serial command issued by the PC is returned with a response once the command is complete. The valid responses are shown in Table
Table 6-2. Serial Response Protocol
REPORT | REPORT DESCRIPTION |
OK | COMMAND COMPLETE |
CE | COMMAND ERROR |
TE <transmit error count> | TX ERROR COUNT (units of bit errors) |
RE <receive error count> | RX ERROR COUNT (units of bit errors) |
All serial commands must end in either a carriage return or carriage return and line feed. All responses end with a carriage return and linefeed.
The serial port settings for the MTK Tester are shown in Table
102 | CY4672 Reference Design Guide, Document # |