7.Regulatory Testing Results
7.1Introduction
The PRoC™ LP RDK leverages the regulatory work done for the CY4636 RDK. The CY4636 LP mouse was tested in a certified lab and meets FCC part 15, Subpart B, Title 47
Testing for the keyboard and bridge is expected in the near future.
Table
Test Parameter | FCC Limit | Measured Value | Margin |
Spurious Radiated Emissions | 54 dBuV/m(Av) | 50.5 dBuV/m | |
Spurious Conducted Emissions | 11.9 dB | ||
Power Spectral Density | 8 cBm/3 kHz | 17.0 dB | |
Output Power | 30 dBm | 2.3 mW | 26.0 dB |
Occupied Bandwidth | >500 kHz | 960 kHz | 460 kHz |
Conducted Band Edge Compliance | 20 dB below fundamental | 7.0 dB | |
Radiated Band Edge Compliance at | 54 dBuV/m(Av) | 51.7 dBuV/m | |
2482 Mhz |
|
|
|
| Industry Canada limit |
|
|
Receiver Radiated Emissions | 46 dBuV/m(QP) | 35.4 dBuV/m |
CY4672 Reference Design Guide, Document # | 105 |