7.Regulatory Testing Results

7.1Introduction

The PRoC™ LP RDK leverages the regulatory work done for the CY4636 RDK. The CY4636 LP mouse was tested in a certified lab and meets FCC part 15, Subpart B, Title 47 CFR–Unintentional radiators, FCC Part 15 Subpart C–Intentional radiators, and Industry Canada RSS-Gen. The follow- ing table outlines the results of the testing.

Testing for the keyboard and bridge is expected in the near future.

Table 7-1. EMC Test Results

Test Parameter

FCC Limit

Measured Value

Margin

Spurious Radiated Emissions

54 dBuV/m(Av)

50.5 dBuV/m

-3.5 dB

Spurious Conducted Emissions

-20 dBc

-31.9 dBc

11.9 dB

Power Spectral Density

8 cBm/3 kHz

-9.0 dBm/3 kHz

17.0 dB

Output Power

30 dBm

2.3 mW

26.0 dB

Occupied Bandwidth

>500 kHz

960 kHz

460 kHz

Conducted Band Edge Compliance

20 dB below fundamental

-27.0 dBc

7.0 dB

Radiated Band Edge Compliance at

54 dBuV/m(Av)

51.7 dBuV/m

-2.3 dB

2482 Mhz

 

 

 

 

Industry Canada limit

 

 

Receiver Radiated Emissions

46 dBuV/m(QP)

35.4 dBuV/m

-10.6 dB

CY4672 Reference Design Guide, Document # 001-16968 Revision **

105

[+] Feedback

Page 105
Image 105
Cypress CY4672 manual Regulatory Testing Results, Test Parameter FCC Limit Measured Value Margin