Creating Labels Using Internal Batch Software

Y is another special font choice that is not actually a font. The Y font selects a graphic image that has already been loaded into the memory module. If this font is selected, enter the name of the graphic image in the Data/Prompt position. This name must be uppercase characters when printing an image.

If any letter or number is entered in the FNT Position other than those specified above, the following error message will appear:

INVALID FONT TYPE

You will need to re-enter the data. After entering the desired font and pressing the return key, the cursor will move to the XW position.

6.The XW and XH positions are used to magnify widths and heights of fonts, and to change the wide/narrow ratio of barcodes.

If you wish to magnify the width of a font, valid responses are 1 through 9 and A through O. The default value is 1 for fonts.

If you wish to magnify the width of a barcode, valid responses are 1 through 9 and A through K. The default is 3 for ratio-based barcodes, 2 for fonts Q & R and 1 for all other barcode fields. If the pixel width is 1, the result will be a 5 mil (.0005") wide bar. If the pixel width is 2, the result will be a 10 mil (.010")wide bar. Pixel sizes by label format are specified in the Print Parameters screen.

Enter the desired XW dimension and press the return key. The cursor will move to the XH position.

44

Allegro2

Page 52
Image 52
Datamax Allegro 2 manual Invalid Font Type