dCS 974 User Manual | Manual for Software Version 1.0x |
dCS Ltd | May 2001 |
|
|
Step 2 – Setting the Sync Source
do this: Switch on the source equipment. If appropriate, load a disk / tape and set the machine in PLAY mode to ensure it is generating a digital audio data stream.
The dCS 974 will be set to sync to the selected Audio Input and the Input Sample Rate will be Auto detected. The unit should lock and the Unlocked indicator should turn off. If you do not want to use an external reference clock, proceed to Step 3.
TOP LEVEL |
|
|
|
| |
|
|
|
|
|
|
Sample Rate Conversion |
|
|
|
| |
|
|
|
|
|
|
Audio Input Select |
|
|
| Default | |
Sync Source |
|
| Audio Input | ||
|
| ||||
|
| AES Loop |
| ||
Input Sample Rate |
|
| AES Loop Term |
| |
|
|
|
| Wordclock |
|
|
|
|
|
| |
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
| Internal |
|
|
|
|
|
| |
|
|
|
|
| |
|
|
|
| Lab Ref (10MHz) |
|
|
|
|
|
| |
|
|
|
|
|
Figure 2 – Sync Source Selection
If a stable clock source is available, you can reduce jitter in your system by syncing to it. Choose one of the following two sections:
Syncing to an External Wordclock
| If you want to synchronise your system to Wordclock from a Master Clock (such |
| as the dCS 992) or other stable source, do the following: |
do this: | Set the Master Clock sample rate to match the source (probably 44.1 or |
do this: | 48kS/s). |
Connect either a Wordclock or AES/EBU output from the Master Clock to the | |
| clock input on the source equipment and ensure it is locked. |
do this: | Connect another Wordclock output from the Master Clock to the WCLK IN |
| connector (upper block of DSD/SDIF connectors) on the dCS 974 rear panel. Fit |
| a 75Ω BNC terminating plug to the nearby LOOP OUT connector. |
| If the source equipment uses |
| Wordclock feed from the Master Clock replaces the Wordclock feed from the |
| source equipment. |
do this: | Scroll down the Sample Rate Conversion menu to Sync Source and press |
| the → button. Scroll down the list to Wordclock and press Set. |
| The Unlocked indicator will light for a few seconds, then turn off as the unit re- |
| locks. |
do this: | Proceed to Step 3. |
Manual part no: DOC1241121A1 | Page 13 | Document No: |
Contact dCS on + 44 1799 531 999 | email to: more@dcsltd.co.uk |
(inside the UK replace + 44 with 0) | web site: www.dcsltd.co.uk |