dCS 974 User Manual | Manual for Software Version 1.0x |
dCS Ltd | May 2001 |
Noise arises from processing rounding errors, and from stop band performance. It is typically around
The conversion process takes time, and the time is dependent on the conversion being carried out, and the filters used. Typical values in microseconds are given for four conversions in the table below.
|
| Group Delay (∝s) |
| Sample Period (∝s) | ||
Conversion | Filter | Filter | Filter | Filter | Input | Output |
| 1 | 2 | 3 | 4 |
|
|
44.1k ⇒ 96k | 1141 | 1131 | 1131 | 1131 | 22.676 | 10.417 |
88.2k ⇒ 44.1k | 1024 |
|
|
| 11.338 | 22.676 |
96k ⇒ 44.1k | 1515 | 1065 | 1065 | 1065 | 10.417 | 22.676 |
96k ⇒ 48k | 868 | 958 | 1028 | 948 | 10.417 | 20.833 |
Table 7 – Group Delays, PCM to PCM transitions
Manual part no: DOC1241121A1 | Page 75 | Document No: |
Contact dCS on + 44 1799 531 999 | email to: more@dcsltd.co.uk |
(inside the UK replace + 44 with 0) | web site: www.dcsltd.co.uk |