dCS 974 User Manual

Manual for Software Version 1.0x

dCS Ltd

May 2001

Noise

Noise arises from processing rounding errors, and from stop band performance. It is typically around –130dB0, but depends on the conversion being used.

Group Delay

The conversion process takes time, and the time is dependent on the conversion being carried out, and the filters used. Typical values in microseconds are given for four conversions in the table below.

 

 

Group Delay (s)

 

Sample Period (s)
Conversion

Filter

Filter

Filter

Filter

InputOutput

 

1

2

3

4

 

 

44.1k 96k

1141

1131

1131

1131

22.676

10.417

88.2k 44.1k

1024

 

 

 

11.338

22.676

96k 44.1k

1515

1065

1065

1065

10.417

22.676

96k 48k

868

958

1028

948

10.417

20.833

Table 7 – Group Delays, PCM to PCM transitions

Manual part no: DOC1241121A1

Page 75

Document No: OS-MA-A0124-112.1A1

Contact dCS on + 44 1799 531 999

email to: more@dcsltd.co.uk

(inside the UK replace + 44 with 0)

web site: www.dcsltd.co.uk