dCS 974 User Manual

Manual for Software Version 1.0x

dCS Ltd

May 2001

 

 

Figure 20 – Transient Performance of 96 kS/s Filter Options

Spurs

Sample rate conversion is a linear process, so spurs are not caused by mechanisms that produce harmonic distortion. Spurs16 are caused by high order images of the baseband input signal aliasing back into the output17. The filtering in the converter has to suppress these.

We measure these spurs for a 1 kHz input signal – typical values are given in dB0 for a -1dB0 sine wave in the table below. The blank cells are two pass conversions, where the performance depends on both conversions.

Input

 

 

 

 

Output Sample Rate (kS/s)

 

 

 

 

Rate

11.02

 

 

 

 

 

 

 

 

 

 

 

(kS/s)

12

16

22.05

24

32

44.1

48

88.2

96

176.4

192

 

5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

11.025

-130

-122

 

-143

-117

 

-136

 

-140

 

 

 

12

-139

-136

 

-131

-135

 

 

-138

 

-137

 

 

16

 

 

-132

-119

-132

-119

-112

-130

 

-137

 

 

22.05

-137

-145

-124

-134

-130

 

-134

-113

-139

 

 

 

24

-121

-134

-127

-142

-137

 

-128

-129

 

-134

 

 

32

 

 

-128

 

 

-133

-123

-131

-107

-134

 

 

44.1

-132

-120

-124

-133

-145

-125

-136

-126

-127

-109

-132

-119

48

-118

-132

-136

-119

-134

-125

-137

-136

-127

-130

 

-132

88.2

-129

-120

-119

-135

-120

-125

-137

-145

-139

-121

-117

-105

96

-97

-126

-138

-116

-135

-139

-117

-137

-119

-139

 

-117

176.4

 

 

 

 

 

 

-137

 

-134

 

-135

 

192

 

 

 

 

 

 

-128

-130

-139

-131

 

-135

 

 

 

 

 

 

 

 

 

 

 

 

 

Table 6 – Typical Spurious Level vs Conversion

16Spurious products

17For example, a 1 kHz tone with a 48 kS/s sample rate in will produce spurs at 2.9 kHz and 4.9 kHz, 6.8 kHz and 8.8 kHz, etc, with a 44.1 kS/s sample rate out.

Manual part no: DOC1241121A1

Page 74

Document No: OS-MA-A0124-112.1A1

Contact dCS on + 44 1799 531 999

email to: more@dcsltd.co.uk

(inside the UK replace + 44 with 0)

web site: www.dcsltd.co.uk