To change between Numerical or Bar level metering, or to change the meter characteristics, return to the Level Meters menu and press → to display the options:
Decay TimeSelect Decay and press Set to display the Decay time options:
These options give the following characteristics:
Normal | the bar length decays away at 32 ms/segment |
Faster | the bar length decays away at 16 ms/segment |
Fastest | the bar length decays away at 11 ms/segment. |
Instant | the bar length decays away completely in 32ms. |
Select the required Decay Time and press Set.
Peak Hold
Select Peak Hold and press Set to display the Peak Hold options:
Scroll down to see the bottom of the list of options:
The unit notes the highest signal peak on each channel and turns on the appropriate meter segment on each bar. The Peak Hold segment remains for the set time and is then replaced by the next signal peak.
The menu options function as follows: