This option is either On or Off.
The unit uses the AES Ref Loop In as a sync link. When On, if the unit detects a sync signal into the AES Ref Loop In, it will sync to it and set up as a Slave. If there is no sync signal coming into the AES Ref Loop In, it will set up as a Master. See section Multiple Channel Sync’ing, page 81 for an explanation, or the
When the option is On, the Status display informs you about the unit’s configuration. If an active signal is connected to the AES Ref Loop In, but it does not carry User bits, the unit thinks it is a Single unit, and the Status display is as follows:
If no signal is connected into the AES Ref Loop In (there is no sync link going in), the unit thinks it is a Master and the Status display is as follows:
If the sync link is connected and active, the unit thinks it is a Slave, and the Status display shows:
For multi channel syncing on DSD to DSD, the sync link does not synchronise all the output Wordclocks. Each unit will have a different phase. Just use the Wordclock from one unit and ignore the rest – the group delays for the signals will not be affected.
Manual part no: DOC1241121A1 | Page 42 | Document No: |
Contact dCS on + 44 1799 531 999 | email to: more@dcsltd.co.uk |